TW-510R
10
5.Operational setting
5-3.To set the double count prevention time
You can set the time for disabling the next receiving as the double counting prevention time
after a signal is received from “TW-510T” and outputted to OUT1 (or OUT2).
Set proper values to prev
ent the double counting by the “
TW-***T
”.
To set the double counting prevention time, use the Rotary switch 1.
For the preset time, you can set it ranging from 0.1 to 1.0 seconds at interval of 0.1 second.
(10-type)
ROT_SW1
Switch
0
1
2
3
4
5
6
7
8
9
Preset
time
(second)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
*
“0.2second” (Switch 1) is already set before shipment.
5-4.To set the relay (OUT1 and 2) output time
You can set the time for outputting a signal to OUT1 (or OUT2) after receiving it from
“TW-**T”.
The relay output time synchronizes with the buzzer sound time.
Set the proper values depending on the devise on which relay output is connected.
To set the relay output time, use the Rotary switch 2.
For the preset time, you can set it ranging from 0.2 to 1.1 seconds at interval of 0.1 second.
(10-type)
ROT_SW2
Switch
0
1
2
3
4
5
6
7
8
9
Preset
time
(second)
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
*
“0.3second”(Switch 1) is already set before shipment.