Page 1: ...tion Control Indicator Display 21D 429D 21D 265D 21D 485D Instruction Manual V1 90 Please use this Instruction manual correctly on reading well Please keep it carefully to be able to read immediately when required ...

Page 2: ...follows 429D 265D 485D 1 Machine types D Large sized 4 digit Single side D5 Large sized 5 digit Single side DW Large sized 4 digit Double side D5W Large sized 5 digit Double side DE Middle sized 5 digit Single side DEW Middle sized 5 digit Double side 2 Item 2 4 items 3 Communication 429 Specific small current radio wave 265 Micro radio wave 485 Wire type For the 485 type only the Display is avail...

Page 3: ...human injury or property damage The type of precautions that should be observed are classified using the following pictorial symbols This pictorial symbol indicates a Reminder to attract an attention This pictorial symbol indicates a Prohibition to prohibit a certain action For the usage to be commonly applied in all the models Avoid using in a place with a plenty of humidity or dust Otherwise abs...

Page 4: ...ord and Plug outlet with wet hands It may cause an accident such as electrical shock etc Do not damage the Power cord A short circuit or heating may cause a fire or electrical shock Do not use the Power plug with dust being adhered A short circuit or heating may cause a fire or electrical shock Do not give a strong impact onto the AC adapter It may cause an accident or machine failure If you find ...

Page 5: ... This operation manual is translated a product for Japan into English This product is based on Japanese Wireless law ...

Page 6: ...h section 6 4 Setting and Installation methods 7 4 1 Installing the Display 7 4 2 Connecting the Power cord 7 4 3 Connecting the Communication cable for 485 Communication type 9 4 4 Setting the communication channel 11 4 5 Setting the equipment No 14 5 Operation 16 6 Applications Direct display 17 6 1 Transmitter 18 6 2 Communication specifications 18 6 3 Changing the error check system 20 7 Warra...

Page 7: ...o because the 21D Series Display will receive and display the data corresponding to the specified communication format optional data can also be displayed via the modem from the computer on behalf of the Controller of either 21D 429C or 21D 265C 1 3 Machine types Types Large sized 21D 4 digit and 5 digit display Middle sized 21DE 5 digit display 2 command type 21D 2 21DE 2 3 command type 21D 3 21D...

Page 8: ...et Plan Actual 152 2 command Target Plan 15 Target Actual 12 Plan Actual 52 Actual Advancement 23 Actual Accomplishment rate 24 4 command Target Plan Actual Advancement 1523 Target Plan Actual Accomplishment rate 1524 1 5 Communication The 21D SERIES Display lets you select the following communication types The Display is used only for receiving Communication Contents 429 Communication method by m...

Page 9: ...29 7375MHz 265 For receiving only Use optional one wave of 41 waves ranging 264 500 265 500MHz 485 For receiving only RS485 x 1 Power consumption MAX47W MAX88W MAX58W MAX111W Weight About 9 0kg About 9 8kg About 9 2kg About 10 1kg 3 command middle sized type 21DE 3 21DEW 3 Indicator character 5 digit x 2 line Symbol 4 digit x 1 line or 5 digit x 3 line 5 digit x 2 line Symbol 4 digit x 1 line or 5...

Page 10: ...1 waves ranging 264 500 265 500MHz 485 For receiving only RS485 x 1 Power consumption MAX38W MAX63W MAX44W MAX84W Weight About 7 2kg About 7 6kg About 7 4kg About 8 1kg 2 command middle sized type 21DE 2 21DEW 2 Indicator character 5 digit x 1 line Symbol 4 digit x 1 line or 5 digit x 2 line 5 digit x 1 line Symbol 4 digit x 1 line or 5 digit x 2 line Display surface Single side Double side Indica...

Page 11: ...ves ranging 264 500 265 500MHz 485 For receiving only RS485 x 1 Power consumption MAX59W MAX111W MAX82W MAX141W Weight About 11 0kg About 12 0kg About 11 4kg About 12 4kg 4 command middle sized type 21DE 4 21DEW 4 Indicator character 5 digit x 3 line Symbol 4 digit x 1 line or 5 digit x 4 line 5 digit x 3 line Symbol 4 digit x 1 line or 5 digit x 4 line Display surface Single side Double side Indi...

Page 12: ...r cord being mounted Power lump Illuminated at power on Power switch Switch to supply power Fuse Fuse Acrylic plate Differrent from Type Shipment time fixation Screws for removing acrylic plate Screws for removing acrylic plate Side panel Fixed main body with4 pieces Antenna Fitting Power switch Power cord eject hole Fuse Acrylic plate Screws for removing acrylic plate 4 pieces on both sides Displ...

Page 13: ...e of display By nature the LED is most visible from the front Install it at an angle so that you can see it from the front 4 2 Connecting the Power cord The product is shipped with Power cord being mounted If you need to disconnect connect the Power cord due to some reasons connect the Power cord according to the manual Disconnect the side panel L Make antenna arranged perpendicular to the side pa...

Page 14: ... side panel R Connect the power cord to the terminal block only after inserting the power cord through the eject hole Connecting it to the terminal block without inserting the power cord through the power cord eject hole does not allow the acrylic plate at back side to be closed Restore the acrylic plate and side panel to their original places Back side Terminal block for connecting the Power cord...

Page 15: ...ck A of Indicator unit and Terminal block B to the Terminal block B of Indicator unit Also for the connection between Indicator units the terminal A should be connected to terminal A and terminal B to terminal B in the same manner as above Remove the side panel of display and acrylic plate at backside while referring to 4 2 Connecting the Power cord and connect them to the terminal block for RS 48...

Page 16: ...both ends of line Turn on the terminating resistance for the Indicator unit connected at end using a daisy chain To turn on off the terminating resistance use the jumper switch on the CPU board inside the Indicator unit Front view of Indicator unit ON OFF of Jumper 2 JP2 for the terminating resistance ...

Page 17: ...t by the rotary switch of wireless modem that is either of TELEMATE III RB 429 Communication type or WCS 300R 265 Communication type built in the Display Set the same channel as the one of equipment at Transmitter The wireless modem is at front of Display Slide the acrylic plate at front to remove that modem Turn off the power source of Display before changing the communication channel Since the c...

Page 18: ...24 429 5375 05 429 3000 25 429 5500 06 429 3125 26 429 5625 07 429 3250 27 429 5750 08 429 3375 28 429 5875 09 429 3500 29 429 6000 10 429 3625 30 429 6125 11 429 3750 31 429 6250 12 429 3875 32 429 6375 13 429 4000 33 429 6500 14 429 4125 34 429 6625 15 429 4250 35 429 6750 16 429 4375 36 429 6875 17 429 4500 37 429 7000 18 429 4625 38 429 7125 19 429 4750 39 429 7250 20 429 4875 40 429 7375 ...

Page 19: ...675 28 265 200 08 264 700 29 265 225 09 264 725 30 265 250 10 264 750 31 265 275 11 264 775 32 265 300 12 264 800 33 265 325 13 264 825 34 265 350 14 264 850 35 265 375 15 264 875 36 265 400 16 264 900 37 265 425 17 264 925 38 265 450 18 264 950 39 265 475 19 264 975 40 265 500 20 265 000 485 Communication type The 485 Communication type does not have channel setting Only the setting for Equipment...

Page 20: ...Equipment No which is precisely matched with the contents of the communication format transmitted from the equipment at transmitter Use the DIPSW 1 to 7 on CPU board to set the Equipment No The setting ranges are 0 to 99 Turn off the power source before changing the setting For the 485 Communication type TELEMATE III and WCS 300 are not built in CPU board DIPSW for setting DIPSW for setting DIPSW ...

Page 21: ...0 ID084 0010101 ID010 0101000 ID035 1100010 ID060 0011110 ID085 1010101 ID011 1101000 ID036 0010010 ID061 1011110 ID086 0110101 ID012 0011000 ID037 1010010 ID062 0111110 ID087 1110101 ID013 1011000 ID038 0110010 ID063 1111110 ID088 0001101 ID014 0111000 ID039 1110010 ID064 0000001 ID089 1001101 ID015 1111000 ID040 0001010 ID065 1000001 ID090 0101101 ID016 0000100 ID041 1001010 ID066 0100001 ID091 ...

Page 22: ... t receive the data normally for 30 seconds except immediately after power supply LED light off the all points light 1 If there are above situation please arrange installation and setup of display and controller 1 It is only case of setting that Display Latch of function setting is No If you use Direct Display way it is only case of setting that Command is lights off after 30 seconds Displayed Com...

Page 23: ...vailable in 265 Communication type Only as a combination with the Controller it can be used If you use combined with either of Controller 21D 429C or 21D 265C this function is not wanted Omit it Configurations of direct display units 429 Communication type 485 Communication type TELEMATE III Unidirectional communication RS 232C signal Equipment No Equipment No Equipment No Equipment No N Max 99 un...

Page 24: ...d via the wireless modem or wired modem to the Display Once the data corresponding to the specified communication format is received the Display displays the data Thoroughly understand the Communication specifications Communication format before use For the setting methods of Communication channel Equipment No see 4 3 Setting the Communication channel and 4 4 Setting the Equipment No 6 2 Communica...

Page 25: ...e Type 0 30H 123 1 31H 523 2 32H 124 3 33H 524 4 34H 152 5 35H 1523 6 36H 1524 1 byte Target Target quantity 0000 9999 5 byte Actual Quantity of productions 0000 9999 5 byte Advancement Degree of advancement 0000 9999 5 byte Accomplishme nt rate Accomplishment rate 0000 9999 5 byte Plan Planned quantity 0000 9999 5 byte ETX End byte 03H 1 byte BCC CRC CCITT of equipment No ETX Devisor of 11021H Cr...

Page 26: ... setting Check system DIPSW 8 CRC CCITT system OFF Compare twice system ON For the Compare twice system unless the same transmitted sentence is repeated twice continuously it will be judged as an error Compared with the CRC CCIT system it takes longer time for error checking however since there is no need to add the BCC the processing at transmitter side can be relieved Also if the compare system ...

Page 27: ...the product or shall be 6 months after shipping substituting goods The warranty periods will be applied the period visited later Note however that free of charge repair under this warranty is limited to the hardware components of the product Even during the warranty period the customer shall be responsible for repair cost if any of the following applies 1 Troubles or damages occurring due to impro...

Page 28: ... the product within 5 years after end of production for a fee However we reserve the right to use substitute parts or devices for repairing purposes if there are unavoidable reasons such as unavailability of service parts Others Independent of the warranty period the product to be repaired shall in principle be brought into our site because of the necessity of using measuring instruments or the li...

Page 29: ...23 Dimensional drawing Dimensional drawing 3 command large sized type 3 command middle sized type The 485D type does not have an antenna For the 265D type the antenna length is different ...

Page 30: ...24 Dimensional drawing 2 command large sized type 2 command middle sized type The 485D type does not have an antenna For the 265D type the antenna length is different ...

Page 31: ...25 Dimensional drawing 4 command large sized type 4 command middle sized type The 485D type does not have an antenna For the 265D type the antenna length is different ...

Page 32: ...HERUTU ELECTRONICS CORPORATION 62 1 Toyooka cho Kita ku Hamamatsu Shizuoka 433 8103 Japan Sales dept TEL 81 053 438 3555 FAX 81 53 438 3411 Website URL https www herutu co jp en E mail info herutu co jp ...

Reviews: