![HEROSE 4182 Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/herose/4182/4182_operating-instructions-manual_2126809028.webp)
Operating instructions
22
Phone +49 4531 509-0
5
Assembly
5.1
Installation position
With regard to the installation position, pay attention to the arrow showing the flow direction. Installation of
the valve in the vertical position. The outlet “C” points vertically upwards.
5.2
Notices regarding the mounting
Use suitable tools.
Open-ended spanners
Torque wrench
Clean tools before the installation
Open the packaging only directly before the mounting. Freedom from oil and grease for oxygen
(O
2
)
Valves for oxygen are permanently marked with “O
2
”.
Only install the valve if the maximum operating pressure and operating conditions correspond to
the marking on the valve.
Remove protective caps or covers before mounting.
Inspect the valve for dirt and damage. DO NOT install a damaged or dirty valve.
Remove any dirt and residues from the pipeline and valve in order to prevent leaks.
Avoid damaging the connections.
The sealing surfaces must remain clean and intact.
Seal the valve with suitable seals.
No sealant (sealing tape, liquid sealing tape) may enter the valve.
Respect the suitability for use with O
2
.
Connect pipelines in a force-free and torque-free manner.
Stress-free mounting.
In order to ensure trouble-free operation, no impermissible static, thermal or dynamic stresses
may be transmitted to the valve. Observe reaction forces.
Temperature-dependent changes in length in the pipework system must be compensated with
expansion joints.
The valve is supported by the pipework system.
The valve must be protected against dirt and damage during construction work.
Check the leak-tightness.
Tightening torques
Connection
Thread
Max. perm.
tightening
torque
[Nm]
A
M40x2, G11/4,
11/4" NPT
100 Nm
B
M40x2, G11/4,
11/4" NPT
100 Nm
C
M26x1, G3/4,
3/4" NPT
80 Nm
6
Operation
In the delivery state the combined pressure regulator is preset to an operating pressure setpoint (see
chapters 6.1 and 6.2). At the customer's request the combined pressure regulator will be set to an
operating pressure setpoint specified by the customer.
The set screw of the combined pressure regulator must be adjusted in order to set or correct an
operating pressure setpoint:
To set the operating pressure setpoint, loosen the locknut and adjust the set screw accordingly.
Clockwise rotation
Operating pressure setpoint is raised
Summary of Contents for 4182
Page 2: ......
Page 6: ......
Page 20: ...Betriebsanleitung 14 Telefon 49 4531 509 0...
Page 34: ...Operating instructions 28 Phone 49 4531 509 0...
Page 48: ...Instrucciones de servicio 42 Tel fono 49 4531 509 0...
Page 62: ...Notice d utilisation 56 T l phone 49 4531 509 0...
Page 63: ...herose com 57 1 1 1 1 2 1 3 2 2 1 4 5 2 2...
Page 64: ...58 49 4531 509 0 2 3 2 4 2 5 2 6 x x 4 2 7...
Page 65: ...herose com 59 3 3 1...
Page 71: ...herose com 65 6 1 4182 1 4186 1 1 12 6 24 16 38 8 12 20 1 2 n 2 n 3 n n 16 38 6 24 1 12...
Page 72: ...66 49 4531 509 0 6 2 4182 3 4186 3 2 10 8 22 20 38 8 12 20 0 8 n 1 7 n 2 7 n 20 38 8 22 2 10 n...
Page 73: ...herose com 67 7 7 1 7 2 7 2 1 7 2 1 2 5 10...
Page 74: ...68 49 4531 509 0 7 3 C 120 80 6 6 6 6 6...
Page 76: ...70 49 4531 509 0...
Page 77: ...herose com 71 1 1 1 1 2 1 3 2 2 1 4 5 2 2...
Page 78: ...72 49 4531 509 0 2 3 2 4 2 5 2 6 4 2 7...
Page 79: ...herose com 73 3 3 1...
Page 85: ...herose com 79 6 1 4182 1 4186 1 1 12 6 24 16 38 8 12 20 1 2 2 3 n 16 38 6 24 1 12...
Page 86: ...80 49 4531 509 0 6 2 4182 3 4186 3 2 10 8 22 20 38 8 12 20 0 8 1 7 2 7 20 38 8 22 2 10 n...
Page 87: ...herose com 81 7 7 1 7 2 7 2 1 7 2 1...
Page 88: ...82 49 4531 509 0 7 3 C 120 Nm 80 Nm 6 6 6 6 6 7 4...
Page 90: ...84 49 4531 509 0...
Page 91: ...HEROSE GMBH ARMATUREN UND METALLE herose com IV Notizen Note Apunte Note...