33
(6) Air cleaner element
(7) Air cleaner housing
6
7
î
Install a new air cleaner element in the
reverse order of removal.
CAUTION
!
!
î
Never wash or clean the viscous filter. Replace
filter element once in every 15000 km.
î
Replace it earlier if it becomes very dirty,
damage on surface or on the sealing area.
Remove the drain tube plug (1) from the tube
and drain the deposit into a suitable container.
Reinstall the drain tube plug.
AIR CLEANER DRAIN TUBE
(1) Drain tube plug
1
(5) Air cleaner element screws/washers
(6) Air cleaner element
6
5
î
Remove the air cleaner element (6)
from air cleaner housing (7).
î
Clean the air cleaner housing using a shop
towel.