HERMOS AG
Gartenstraße 19 • 95490 Mistelgau
Phone: +49 9279 991 - 0
LFM 4x Reader Rev1.4
back to the table of contents
68
Customer manual
LFM 4x Reader
RFID
WE GENERATE SOLUTIONS
The following examples are based on the standard ASC-I1 protocol. The range of the Reader
ID is set from 1 to 4 in this case:
V
– Query software version
>> V1
<< v14C464D3449312E35
Command
V
Reader-ID
1
Software version
‚4C464D3449312E35 ‘
ASCII
„ LFM4I1.5“
I
– automatically tune RF module (antenna port 2)
>> I208
<< i2
Commandl
I
Reader-ID
2
(Tuning Antenna port 2)
J
– RF module Read out tuning value (Antenna port 2)
>> J2
<< j201
Command
J
Reader-ID
2
(Antenna port 2)
Data
01
(voting value)
X
– Read data (Reading from page 1 of the multipage transponder)
>> X101
<< x1014142434445464748
Command
X
Reader-ID
1
(reading on antenna port 1)
Page
01
Data
‚4142434445464748‘
ASCII
„ABCDEFGH“
R - Automatic reading on antenna port 1
<< R1013132333435363738
>> r1
Command
R
Reader-ID
1
(automatic reading on antenna port 1)
Page
01
Data
‚4142434445464748‘
ASCII
„ ABCDEFGH „
W
– Write data (Write antenna port 2, page 16 Multipage)
>> W2103132333435363738
<< w2
Command
W
Reader-ID
2 (Write to antenna port 2) Page
10
(10hex = page 16dec.)
Data
‚3132333435363738‘
ASCII
„12345678“