Structure of the response message:
Länge Actionr CMD
Success-Code
opt.Headnr
opt. Daten
Erklärung
0x03
0x00
0x6E (‚n‘)
0x00 (ok)
ResponseTriggered
Reset
0x12
0x01
0x76
(‚v‘)
0x00 (ok)
0x53, 0x57,…,
0x30
Response Get
Softwareversion
0x04
0x02
0x73(‚s‘)
0x00 (ok)
0x01
Response Get UDP
Revision 0x01
0x06
0x03
0x66(‚f‘)
0x00 (ok)
0x01
0x1A, 0x0F
Response Get
Parameter Head 0x01
Par 0x1A Value 0x0F
0x03
0x03
0x66(‚f‘)
0x36 (invalid
parnr)
Response Get
Parameter
Error 0x35 Invalid
parnr
0x04
0x04
0x70(‚p‘)
0x00 (ok)
0x01
Response Set
Parameter Head 0x01
0x04
0x04
0x70(‚p‘)
0x37(invalid
value)
Response Set
Parameter
Error 0x37 Invalid
value
0x05
0x05
0x69(‚i‘)
0x00 (ok)
0x01
0x04
(Tuningwert)
Response Tuning
Head 0x01 Wert 0x04
0x03
0x05
0x69(‚i‘)
0x35 (invalid)
Response Tuning
Error 0x35 Invalid
Value
0x0D
0x06
0x78(‚x‘)
0x00 (ok)
0x01
0x02,
0x31…0x38
Response Read Head
0x01
Page 0x02
Data
0x31…0x38
0x03
0x06
0x78(‚x‘)
0x34 (No Tag)
Response Read
Error 0x34 NoTag
A success code of 0x00 in the response message indicates the correct execution of the