Performing maintenance
32
Maintenance instructions
8.13 Check software
INFORMATION
New software version may fix bugs and include feature enhancements.
The manufacturer recommends testing and updating the software.
Check software version
Test criteria
Remarks / values
Yes
No
•
Is the installed software version up to date?
If No
Perform update.
Check software version
Test criteria
Remarks / values
Yes
No
•
Installed software version after update:
8.14 Checking the power supply
DANGER
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
NOTICE
Risk of property damage from using wrong wires
When servicing, only use wires with silicone insulation.
Check supply voltage
Type of connection
3PE / AC 50/60 Hz, 3NPE / AC 50/60 Hz, 400 V
Test criteria
Actual value (V)
L1:
L2:
L3:
Prerequisite
Cooking chamber empty
1. Start cooking in the cooking mode
Convection
with core
temperature.
Set about 250 °C (482 °F).
Unit is called at maximum load.
2. When heating up: Measure current consumption.
3. Stop cooking program after measurement.
FM06-140
Summary of Contents for FlexFusion ELECTRIC SPACESAVER PLUS TEAM
Page 2: ...2 Maintenance instructions...
Page 35: ...Performing maintenance 35 Maintenance instructions Notes and remarks FM06 140...
Page 42: ...Acceptance of maintenance 42 Maintenance instructions FM06 140...
Page 43: ......
Page 44: ...FM06 140 Henny Penny Corp Eaton Ohio 45320 Revised 2 7 2022...