Performing maintenance
21
Maintenance instructions
8.5.1 Door latch upper and lower cooking chamber
Check the function of the interlock
Test criteria
Remarks / values
Yes
No
•
Lock must be actuated (locking and unlocking).
If No
Change door latch.
Check the function of the interlock
Test criteria
Remarks / values
Yes
No
•
Locking plunger is undamaged and not worn.
If No
Replace locking block
Check the function of the interlock
Test criteria
Remarks / values
Yes
No
•
Locking plunger is firmly seated on the housing.
If no
Tighten the screw connection.
8.6 Check water connection
What type of water softening is present?
Test criteria
Remarks / values
Yes
No
•
Water filter available.
•
Replacement date of the water filter?
•
On-site water softening system available.
Checking the flexible conduit on the unit
Test criteria
Remarks / values
Yes
No
•
Flexible conduit is tight (no deposits or corrosion).
If No
Change flexible conduit.
FM06-140