Performing maintenance
31
Maintenance instructions
Image: Pay attention to the installation position of the air filter
Prerequisite
Unit switched off
Unit has cooled down
1. Remove the filter drawer with the filter.
2. Unclip condensate baffle.
3. Lift the air filter out of the holder at the rear.
The air filter drops out of the front holder.
4. Remove the air filter from the front.
5. Insert a new air filter into the holders.
6. Make sure that the filter is in the correct position.
The air filter lies in the holders.
7. Clip in condensate baffle.
8. Push the filter drawer in as far as the end stop.
Air filter changed in the recirculation hood.
Conclusion
Prerequisite
Disconnect the recirculation and associated unit from power
All components dry
1. Hook the condensation baffle back in.
2. Insert filter drawer in recirculation hood.
Recirculation hood ready for operation again.
Filter mat yellow replaced, filter holder cleaned
Test criteria
Remarks / values
Yes
No
•
Filter mat yellow exchanged.
•
Filter holder cleaned.
•
Condensation area cleaned.
Filter mat yellow replaced, filter holder cleaned
Test criteria
Remarks / values
Yes
No
•
Air filter replaced.