Performing maintenance
24
Maintenance instructions
Check the steaming unit (see service level)
Test criteria
Remarks / values
Yes
No
•
Humidification unit works perfectly.
•
Water volume measured in the DynaSteam test indi-
cated.
–
Unit in "ml" or "fl oz".
If No
Troubleshooting according to service manual.
Check solenoid valve vapour release (service level / relay test)
Test criteria
Remarks / values
Yes
No
•
Solenoid valve works perfectly.
If No
Troubleshooting according to service manual.
Inform operator.
Check siphon pump (service level / relay test)
Test criteria
Remarks / values
Yes
No
•
Siphon pump works perfectly.
If No
Troubleshooting according to service manual.
Inform operator.
Check pump circulation (service level / relay test)
Test criteria
Remarks / values
Yes
No
•
Pump circulation works properly.
If No
Troubleshooting according to service manual.
Inform operator.
Check motor cooking chamber for noise
Test criteria
Remarks / values
Yes
No
•
Motor cooking chamber runs virtually noiselessly.
If no
•
Check fan wheel for imbalance.
•
Recommendation of the manufacturer: Change motor and fan wheel.
Check electrical contacts - Carry out inspection of wiring harness (cable and contacts)
Test criteria
Remarks / values
Yes
No
•
Contacts are free of scorch marks.
If No
Change electronic components.
FM06-140
Summary of Contents for FlexFusion ELECTRIC SPACESAVER PLUS TEAM
Page 2: ...2 Maintenance instructions...
Page 35: ...Performing maintenance 35 Maintenance instructions Notes and remarks FM06 140...
Page 42: ...Acceptance of maintenance 42 Maintenance instructions FM06 140...
Page 43: ......
Page 44: ...FM06 140 Henny Penny Corp Eaton Ohio 45320 Revised 2 7 2022...