17
7 Troubleshooting
Malfunction/Fault signal
Possible Cause
Corrective Action
No start signal.
– Reservoir is empty.
The error message (with beeping)
blinks in the digital display:
– Automatic reservoir refilled but not
yet pressurized. The error message
blinks in the digital display:
Tank = Reservoir.
Inactive = Not pressurized.
– Plug on the socket XS1: Start 16 is
loose.
– Footswitch 15 defect.
– Control unit is defect.
● Refill reservoir (see Section 5.2).
The error message appears
previously in the digital display:
● Pressurize the automatic reservoir.
● Press button . The automatic
reservoir is pressurized.
● Switch the power switch 7 to the
position O (OFF).
● Tighten the screws of the plug.
● Switch the power switch 7 to the
position I (ON).
● Replace the Footswitch 15.
● Henkel Service.
8 Pin Assignment
Caution!
Never connect any external voltage on pin 9 of XS1 or XS2!
8.1 XS1: Start via Footswitch