13
5 Dispensing
5.1.2.2 Continuous Mode
This mode of operation is used for wettings of varying lengths or for the application of
beads.
● With the pressure regulator
8
set the
dispensing pressure to 0.50 bar (approx.
7 psi). An error
message „
Press. 0.83
NOK
“ with beeping is possible. The
value
0.83
[bar/psi] is only an example
for the indicated dispensing pressure
(see Chapter 7).
● Press button to store the dispensing
pressure setting as the comparison
value for automatic pressure monitoring.
The error message with beeping is
eliminated.
● Press button . The lighting of the LED
in button indicates continuous mode.
The indication of the dispensing time in
the digital display is set to 0.00 s and
blinks.
● Press the Footswitch
15
until the
dispensed quantity is roughly achieved.
If the dispensed quantity is too small:
● Increase the dispensing pressure and store. Check the dispensed quantity again.
Repeat this sequence until the desired dispensed quantity is roughly achieved.
– Switching back to time controlled mode
without storage
of the dispensing time by
renewed pressing of button . The LED in button extinguishes. In the digital
display, the dispensing time previously stored for the time controlled mode reappears.
– Switching back to time controlled mode
with storage
of the dispensing time by
pressing button . The LED in button extinguishes. The indicated dispensing time
is stored and the display stops blinking.
If the desired dispensed quantity is not achieved:
● With a larger (or smaller) dispensing needle, repeat the steps of Section 5.1.2.1.
Summary of Contents for Loctite 135550
Page 1: ...22121 97102 135550 ...
Page 2: ...2 ...
Page 18: ...18 8 Pin Assignment 8 2 XS1 External Start 8 3 XS1 Start via Promixity Switch ...
Page 20: ...20 9 Declaration of Conformity ...
Page 21: ...22121 ...
Page 37: ...37 8 Steckerbelegung 8 2 XS1 Externer Start 8 3 XS1 Start über Näherungsschalter ...
Page 39: ...39 9 CE Konformitätserklärung ...