7
2 Description
3
Button
Button for the storage of the new values set for the dispensing time [s] and the
dispensing pressure [bar] or [psi].
When the indication of the dispensing time [s] in the digital display blinks, the
indicated dispensing time is stored by pressing button and the display stops
blinking.
For an error message „
Press. 0.83 NOK
“ with beeping, the error message is
acknowledged by pressing button . The value
0.83
[bar/psi] is only an
example for the indication of a dispensing pressure (see Chapter 7).
If the error message „
PRESS ENTER; >Tank Inactive<
“ appears, the automatic
reservoir (
Tank
) is pressurized by pressing (
PRESS
) button (
ENTER
) (see
Section 5.2.1).
4
Button
Button for filling the product line (see Section 5.1.1).
The LED lights as long as button is pressed.
When button is pressed in time-controlled mode, the dispensing time is not
changed.
The product is dispensed as long as button is pressed.
When button in pressed in continuous mode, the dispensing time is changed
(see Section 2.3)
5
Button
Button for switching the measuring units for the dispensing pressure in the digital
display.
After each pressing of button the indication of the selected dispensing
pressure in the digital display changes to the other measuring unit [bar] or [psi]
with the corresponding value.
6
Button
Button for switching from time controlled mode to continuous mode.
The lighting of the LED in button indicates continuous mode (see Section
5.2.2.2).
By pressing button the indication of the dispensing time in the digital display is
set to 0.00 s and blinks. During dispensing, the elapsed dispensing time is
indicated in the digital display beginning each time with 0.00 s. The last
dispensing time remains displayed until the next start.
– Switching back to time controlled mode without storage of the dispensing time
by renewed pressing of button . The LED in button extinguishes. In the
digital display, the dispensing time previously stored for the time controlled
mode reappears.
– Switching back to time controlled mode with storage of the dispensing time by
pressing button . The LED in button extinguishes. The indicated
dispensing time is stored and the display stops blinking.
7
Power Switch I/O (ON/OFF)
The control unit is switched on and off with the power switch.
When a product reservoir is connected, the following also applies:
Position I (ON)
– The reservoir is automatically pressurized with the dispensing
pressure set on the precision pressure regulator.
Position O (OFF)
– The reservoir is automatically depressurized.
Summary of Contents for Loctite 135550
Page 1: ...22121 97102 135550 ...
Page 2: ...2 ...
Page 18: ...18 8 Pin Assignment 8 2 XS1 External Start 8 3 XS1 Start via Promixity Switch ...
Page 20: ...20 9 Declaration of Conformity ...
Page 21: ...22121 ...
Page 37: ...37 8 Steckerbelegung 8 2 XS1 Externer Start 8 3 XS1 Start über Näherungsschalter ...
Page 39: ...39 9 CE Konformitätserklärung ...