![Henkel 1447728 Operating Manual Download Page 8](http://html1.mh-extra.com/html/henkel/1447728/1447728_operating-manual_2123955008.webp)
8
3 Technical Data
Power supply
Power supply 100-240 V AC, 50/60 Hz
Power consumption
Approx. 100 W
Power protection
Glass tube, fine wire fuse, 5 A semi time-lag
Internal control voltage
24 V DC
Power connection
Cold appliance coupling IEC 320 acc. to VDE 0625
Dimensions W x H x D
12.2x5.3x14.4 inch (310x135x365 mm)
Weight
Approx. 3.5 kg (7.7 lbs)
Operating Temperature
+10 °C to +40 °C (+50 °F to +104 °F)
Storage Temperature
-10 °C to +60 °C (+14 °F to +140 °F)
Continuous noise level
< 30 dB(A)
Life cycle UV Line Array
Up to 20,000 hours
4 Installation
4.1 Environmental and Operating Conditions
– No direct sunlight.
– No condensing humidity.
– No splash water.
4.2 Space Requirements
Controller LED Array