Appendix 39/46
RE 51550-B/04.2021,
Hengst Filtration GmbH
Analog output
Selectable current or voltage output
(4 - 20 mA, 2 - 10 V, 0 - 10 V or 0 - 5 V)
Tolerance
± 0.5% FS
Load Ω
= (U
B
- 8 V) / 0.02 A
Switching output
PNP switching output
Selectable switching function and switching output
Switching current
max. 0.2 A per output
Temperature
measurement
Measurement range
-20 °C to +120 °C
Accuracy
± 1.5 % FS
Analog output
Selectable current or voltage output
(4 - 20 mA, 2 - 10 V, 0 - 10 V or 0 - 5 V)
Tolerance
± 0.5% FS
Load Ω
= (U
B
- 8 V) / 0.02 A
9.4 Outputs WGM-B
Version
2A1S
1D0S
Connector (base)
1 x M12 – 8-pin
1 x M12 – 4-pin
Switching output
(fixedly set)
X
IO-Link
X
Analog output for
humidity
X
Analog output for
temperature
X
9.5 Outputs WGM-R / WGM-D
Version
2A2S
1D1S
Connector (base)
Display & remote
1 x M12 – 8-pin
1 x M12 – 4-pin
Sensor connection
socket (bottom) remote
1 x M12 – 8-pin
1 x M12 – 8-pin
Switching outputs
2 x
1 x
IO-Link
X
Analog output for
humidity
X
Analog output for
temperature
X