32/46 Operation
Hengst Filtration GmbH
Hengst Filtration GmbH
, RE 51550-B/04.2021
, RE 51550-B/04.2021
5.1.9.5 Defining the switching output to be logged
Here, the switching output to be logged is selected. Only one switching output can
be logged.
The following options are available:
Selection:
OUTi
to
OUTx
Logging of the switching output.
Important notice
:
The values are saved from the volatile to the non-volatile memory approx.
every three hours.
5.1.9.6 Delay to min / max storage of humidity
In order to record reliable values with fluctuating input variables, a delay can be
set for storing the minimum and maximum humidity. The time period in seconds
in which the signal must be permanently present before the humidity is logged is
specified here.
The following options are available:
Setting range: 0…100 seconds
▶
Open the value list with the
u
key.
▶
Set the value with the
q
and
p
keys and confirm with the
u
key (e.g.
5 seconds). The device returns to the submenu.
5.1.9.7 Delay to min / max storage of the temperature
In order to record reliable values with temperature variations, a delay can be set
for storing the minimum and maximum temperature variation. The time period in
seconds in which the signal must be permanently present before the temperature is
logged is specified here.
The following options are available:
Setting range: 0…100 seconds
▶
Open the value list with the
u
key.
▶
Set the value with the
q
and
p
keys and confirm with the
u
key
(e.g. 5 seconds). The device returns to the submenu.