1. Operation mode semi- automatic / automatic
When semi-automatic mode is set the drive will not close automatically. The potentiometer is without function.
When the automatic mode is set the drive closes automatically.
2.
Dead man’s control:
When dead man’s control is activated the drive will only operate, as long as an input is applied.
S
witch 1 is inactive, when dead man’s control is selected.
3. Push & go:
With push & go enabled the drive starts to move, as soon as the door leaf is pushed manually.
4. Reaction on obstruction:
When reverse is set the drive stops and starts to move in the opposite direction, as soon as an obstruction is detected.
Otherwise it will stop until a new command is given. This is only possible in semi-automatic mode).
5. Closing speed:
By default the closing speed is slower than the opening speed. The closing speed can be set as fast as the opening speed, by
setting this switch to ON>
6. To 8. Maximum door speed
The maximum speed has to be set via these switches.
Maximum speed is dependent on the door leaf weight according to DIN EN 18650.
6: Weight of door leaf up to 80 kg > Maximum speed is 20cm/s
7: Weight of door leaf up to 80 kg > Maximum speed is 23cm/s
8: Weight of door leaf up to 80 kg > Maximum speed is 26cm/s
When no switch is activated, the lowest speed is set (20 cm/s).
When more than one switches are activated, a reduced speed is set (12 cm/s).
Perform Reset
Switch power supply on.
Control device in delivery status or after power cut:
Red LED blinks continuously twice with a short break of 1.5sec.
Press RESET for about 2 seconds.
Red LED blinks continuously.
Check driving direction of motor with control keys:
When pressing OPEN, door has to open and when pressing CLOSE, door has to close.
→ when driving direction is wrong:
Swap motor cables (terminals MA and MB), check driving direction again.
Move door in middle position by pressing and holding the control keys.
Press RESET for about 2 seconds.
Red LED lights up permanently,
green LED lights up during motor activity.
Door moves in the open position,
Door moves in the closed position,
Door moves in the open position.
LED’s go out.
Check functionality
Test, if the door shows desired behavior.
In case of malfunction check electrical connections and configurations.
→ for electrical connections refer to chapter 5.3 of the Evolve Motor and Wiring Fitting Instructions supplied
→ for configuration refer to chapter 6.1 of the Evolve Motor and Wiring Fitting Instructions supplied
→ Repeat initial operation, if necessary.
Initial operation is completed, when function is correct.
Quick overview
– Wiring wall mounted socket
For detailed operation and programming instructions please consult the separate Evolve Motor and Wiring Fitting Instructions
supplied