Please Note 

The original language of these instructions are English. 

The airborne noise of the system under normal operating conditions 
does not exceed 70dB (A). 

General Safety Precautions 

This installation is intended for professionally competent personnel 
only. 

Installation, Electrical connections and adjustments must be performed 
in accordance with Good Working Methods and in compliance with 
applicable regulations. Before installing the product, carefully read the 
instructions. Bad Installation could be hazardous. 

The packaging material (plastic, polystyrene, etc.) should not be 
discarded in the environment or left within the reach of children, as 
these are a potential source of hazard. 

Before installing the product, make sure it is in perfect condition.  

Do not install the product, make sure it is in perfect condition. Do not 
install the product in an explosive environment and atmosphere; gas or 
inflammable fumes are a serious risk hazard. Before installing the 
system, ensure all structural changes relating to safety clearances and 

protection or segregation of all areas where there is a risk of being 
crushed, cut or dragged, and danger areas in general. 

Make sure the existing structure is up to standard in terms of strength 
and stability. 

Each installation must clearly show the identification details of the 
motorized door or gate. 

Apply hazard area notices required by applicable regulations. 

The electricity supply must be isolated at tis source before attempting 
installation or maintenance. 

Disclaimer 

PC Henderson nor the motor unit manufacturer take responsibility for 

failure to use Good Working Methods in building the frames to be 

motorized or for any deformation occurring during use. PC Henderson 

and the motor declines all responsibility in the event of component 

parts being fitted that are not compatible with the safe and correct 

operation. 

For repairs or replacements of products only original spare parts must 
be used. 

Installer responsibility 

The installer should provide technical documentation once the 

installation is complete, this should include. 

EC declaration of conformity with machinery directive  

Installation manual 

Maintenance / Trouble shooting guide (supplied in the drive 
unit manufacturer operation manual) 

The installer is responsible for affixing final CE mark upon 
the installation.

 

 

668775 – LVL02 – JUNE 2019 

Tighten to position stops 

Summary of Contents for Evolve Glass SIM Kit

Page 1: ... specifications must be respected in especially maximum weight restriction of the door leaf Any other use of this product is considered inappropriate use It is not guaranteed that this product will work in combination with fittings motors or other electronic devices supplied by other manufactures The appliance is only to be used with the power supply unit provided Before you commence work please r...

Page 2: ...ations End elevations Tools required Electricians Screwdriver Posi Head Screwdriver 3 4 5mm Allen keys Scissors Torque Wrench and 6mm bit Electric Drill twist drill Tape Measure Spirit Level 3 10 13mm Spanner ...

Page 3: ...Installation System layout CLOSED POSITION ...

Page 4: ...Quick overview Wiring wall mounted socket For detailed operation and programming instructions please consult the separate Evolve Motor and Wiring Fitting Instructions supplied ...

Page 5: ...Fused Spur Not PCH Motor Unit 24V Transformer Wall mounted control device inputs Transformer input Remote sensor or additional switch input ...

Page 6: ...is off B Potentiometer Detail Automatic closing delay time To prolong automatic closing delay time Turn potentiometer Clockwise To reduce the automatic closing delay time Turn potentiometer Anti clockwise NOTICE Potentiometer have a right and left stop point which must not be overtightened Adjust potentiometer slightly with an appropriate tool Damage to control device may result in malfunction Qui...

Page 7: ...ated the lowest speed is set 20 cm s When more than one switches are activated a reduced speed is set 12 cm s Perform Reset Switch power supply on Control device in delivery status or after power cut Red LED blinks continuously twice with a short break of 1 5sec Press RESET for about 2 seconds Red LED blinks continuously Check driving direction of motor with control keys When pressing OPEN door ha...

Page 8: ...1 Secure motor unit to track by inserting block into track and tightening bolts to clamp over bottom of track Track Connector block Connector Block Spacer Track Motor ...

Page 9: ...M6x25 Bolts 180mm Offset to accommodate door under motor unit 2 Door and hardware preparation overview 3 Attach glass clamps Panel positioned under motor highlighted ...

Page 10: ... clamp b Locate second half of glass clamp over knee of first c Secure glass clamp with screws d Attach spacer block with screws to top of clamp e Attach belt clamp with screws on to top of spacer a Position first half of glass clamp b Locate second half of glass clamp over knee of first c Secure glass clamp with screws a b c ...

Page 11: ...fixing installation spacing between brackets is 600mm MAX Use suitable wall anchors NOT PCH 6 Secure track soffit fix installation spacing between brackets is 600mm MAX Use suitable wall anchors NOT PCH 1 SS bracket Fit suitable wall anchors a d c b e ...

Page 12: ...Toothed belt Tension wheel arrangement in track 8 Remove covers to allow toothed belt to be attached ...

Page 13: ...9 Hang glass door 10 Set door height ...

Page 14: ...oothed belt Push tension wheel assembly so that the belt is torte and secure assembly in position by tightening the M6 grub screw 11 Loosen belt clamp Cut belt to length Tighten to secure belt Tighten to clamp belt ...

Page 15: ...14 Set track stops to limit travel Tighten once position set 13 Fit Door Guide using spirit level Adjust door stop if required before fixing to ensure door is vertical ...

Page 16: ...ere is a risk of being crushed cut or dragged and danger areas in general Make sure the existing structure is up to standard in terms of strength and stability Each installation must clearly show the identification details of the motorized door or gate Apply hazard area notices required by applicable regulations The electricity supply must be isolated at tis source before attempting installation o...

Page 17: ...moving Do not allow children to play or stay within the field of action of the motorised door Keep remote control or any other control devices out of reach of children In order to avoid possible involuntary activation of the motorised door In the case of breakdown or malfunction of the product disconnect form the mains do not attempt to repair or intervene directly contact only qualified personnel...

Page 18: ......

Page 19: ...e Installation at Installation address Conforms to Directive States that it fulfils the application portion of the following standard Date Location of signature Signature of the person legally responsibility This completed document forms part of the European conformity CE marking to be completed by installer and forwarded to end user Evolve 80kg Evolve SIM Kit Evolve Glass 2006 42 CE Machinery dir...

Page 20: ...Must be kept for ten years from installation date ...

Page 21: ... details of the motorized door or gate The installer should apply hazard area notices required by applicable regulations such as that shown below The installer must affix and complete the data tag supplied to the final installation in a suitable prominent position ...

Page 22: ...on of component factors Maintenance interval Planned replacement schedule Tension wheel assembly 668640 Supports belt movement within machine Cracking excessive wear slipping From New Six months once a year thereafter Every 10 Years of service Wheel cover 668323 Moving part protective cover Cracking excessive wear slipping From New Six months once a year thereafter Toothed belt 668605 Provides mov...

Page 23: ... Or sooner dependent upon operating conditions Replacement only recommended when apparent excessive wear affects the performance of the installation ...

Page 24: ...el Description Dimension and Weight Location List of Components Installed Motor Drive Unit Switch Remote fob Motion detector Sign off Check Sheet Warning of residual risks and of foreseeable improper use Inform the end user of risk points regarding risk and foreseeable improper risks Declaration of conformity filled out CE Label completed installed in suitable location Warning sings installed in s...

Page 25: ...Details Details Installation Start Up Adjustments Maintenance Repairs Alterations Installation Start Up Adjustments Maintenance Repairs Alterations Installation Start Up Adjustments Maintenance Repairs Alterations Installation Start Up Adjustments Maintenance Repairs Alterations Description of the work ...

Reviews: