In case the supply cable is not fitted with a plug, 

connect a standardized plug (3P+T) to the 

supply 

cable (in some models the supply cable is supplied 

with plug).

To connect the plug to the supply cable, follow these 

instructions:

• 

 the brown (phase) wire must be connected to 

the terminal identified by the letter L1

• 

 the blue or grey wire must be connected to 

the terminal identified by the letter L2

• 

 the black or grey wire must be connected to 

the terminal identified by the letter L3

• 

 the yellow/green (ground) wire must be con-

nected to the terminal identified by the letter 

PE or by the symbol      .

In any case, the connection of the yellow/green wire 

to the PE terminal       must be done in order that in 

the event of tearing of the power supply cable from 

the plug, the yellow/green wire should be the last 

one to be disconnected.

The outlet should be protected by the proper 

protection fuses or automatic switches.

Notes:

• 

 

Periodically inspect supply cable for any 

cracks or exposed wires. If it is not in good 

conditions, have it repaired by a Service Cen-

tre.

• 

 Do not pull violently the input power cable to 

disconnect it from supply.

• 

 Do not squash the supply cable with other ma-

chines, it could be damaged and cause electric 

shock.

• 

 Keep the supply cable away from heat sorces, 

oils, solvents or sharp edges.

• 

 In case you are using an extension cord, try to 

keep it well straight and avoid its heating up.

SAFETY INSTRUCTIONS

For your safety, before connecting the power source 

to the line, closely follow these instructions:

• 

 An adequate switch must be inserted before 

the mains outlet; this switch must be equip-

ped with time-delay fuses;

• 

 The connection with ground must be made 

with a plug compatible with the above men-

tioned socket;

• 

 When working in a confined space, the power 

source must be kept outside the welding area 

and the ground cable should be fixed to the 

workpiece. Never work in a damp or wet area, 

in these conditions.

• 

 Do not use damaged input or welding cables

• 

 The welding torch should never be pointed at 

the operator’s or at other persons’ body;

• 

 The power source must never be operated 

without its panels; this could cause serious 

injury to the operator and could damage the 

equipment.

CONNECTION TO GROUND CABLE

Connect the dinse plug to the socket and the work 

cable clamp to the piece to be cut or to the metallic 

workbench. Take following precautions:

• 

Verify that there is a good electrical contact 

particularly if insulated or oxidated coated 

sheets are cut. 

• 

Make ground connections as close as possi-

ble to the cutting area. The use of the metallic 

structures which are not part of the workpie-

ce, such as the return cable of the cutting 

current, may endanger the safety system and 

give poor cutting results. 

• 

Do not make a ground connection on the pie-

ce which has to be removed.

TORCH CONNECTION

Ensure unit is off and unpluged from the power 

receptacle.

Figure 11
Supplied torch, manual or automatic, has a quick 

connection system called “H Fit” . Correctly align the 

“H Fit” pins and connect it to the connector on the 

front panel of the unit by handscrewing the plastic 

ring.

WARNING!: Before starting the cutting 

operations verify that the parts are pro-

perly assembled by inspecting the head of 

the torch as shown on paragraph “Torch 

Maintenance”.

TORCH CONSUMABLE PARTS MOUNTING

Position the torch with the outside protection nozzle 

facing upward to prevent these parts from falling out 

when the nozzle is removed.  

WARNING: Wait the torch has completely 

cooled before replacing torch parts to avoid 

any damage to the torch head.

To change the torch consumable parts use the 

following procedure:

1. 

Unscrew and remove the shield cup from the 

Torch Head Assembly. 

2. 

Remove the tip, gas distributor, and electrode. 

3. 

Install the electrode, gas distributor, and tip. 

Choose the correct consumable parts, refer 

to the paragraph “Torch consumable parts 

selection”.

4. 

Hand tighten the shield cup until it is seated 

on the torch head. If resistance is felt when 

installing the cup, check the threads before 

proceeding.

5. 

if necessary, install also the spacer. 

Summary of Contents for PC EVO 126

Page 1: ...MANUALE D ISTRUZIONE IT 3PH PLASMA CUTTING UNIT UNIT DI TAGLIO AL PLASMA 3PH INSTRUCTION MANUAL EN PC EVO 76 PC EVO 86 PC EVO 126...

Page 2: ...NANCE EN 13 OPERATING FAULTS EN 14 TROUBLESHOOTING EN 14 TORCH CONSUMABLES A C INDICE PREMESSA IT 1 SICUREZZA IT 1 AVVERTENZE IT 1 PROTEZIONE PERSONALE IT 2 RADIAZIONI LUMINOSE IT 2 AREA OPERATIVA IT...

Page 3: ...elettroniche La raccolta ed il riciclaggio separati delle apparecchiature da rottamare in fase di smal timento favoriscono la conservazione delle risorse naturali e garantiscono che tali apparecchiatu...

Page 4: ...ck and face including the sides against the light of the electric arc glare from The colored filter inactinic filter must be kept clean at all times Should it break or dete riorate Fig 3 replace it wi...

Page 5: ...e concentration of pollutants does not exceed the permitted limits Fig 6 In addition all welding operations must be carried out on metal surfaces devoid of rust and paint to avoid the formation of haz...

Page 6: ...with the maximum power of the appliance and its voltage please check the information on the plate and in conformity with the norms and regulations in force The ground single phase or three phase conn...

Page 7: ...g or cutting operation always make sure that no incandescent or burning material has been left in the area Make sure the earth connection is good a defective ground connection may result in an electri...

Page 8: ...perfor mance of the product you have just pur chased please refer to the values on the information plates GENERAL INFORMATION INSTALLATION Be sure to locate the welder according to the following guide...

Page 9: ...s Do not use damaged input or welding cables The welding torch should never be pointed at the operator s or at other persons body The power source must never be operated without its panels this could...

Page 10: ...In the case that the cutting table to be connected requires a different voltage it is possible to set a 1 20 reduction FIG 13 Remove the tin bridge on PS1 50 Tin solder the two points of PS1 20 COMPR...

Page 11: ...cutting current when unit is on during pilot arc time views the pilot arc current and during cutting views the cutting current It views the adjusted air pressure bar by pushing the air drain key B 4...

Page 12: ...set the secondary parameters C Air Pressure Indication LEDs Green LED OK ON correct air pressure Figure 15 A B C E D H G F Red LED Increase ON too low air pres sure Red LED Decrease ON too high air pr...

Page 13: ...art Fig 16 Figure 16 to supply primary power to the system GROUND CABLE Check for a solid ground cable connection to the workpiece AUTOMATIC PURGE SYSTEM Place the ON OFF switch to the ON position Act...

Page 14: ...the adjusted current output To increase width Increase the standoff and or the current Decrease the speed and or the angle To decrease width Increase the speed and or the angle Decrease the standoff...

Page 15: ...advisable to replace electrode and tip AT THE SAME TIME Respect assembly order of torch parts reser ved compared to disassemblage Be carefull that distributing is assembled pro perly Reassemble shiel...

Page 16: ...o thick contaminated air humidity oil excessive pilot arc arc ignitions in the air Improperly assembled torch torch tip contacting workpiece damaged or loose torch head components non genuine Manufact...

Page 17: ...h trigger Refer to Maintenance paragraph Faulty Main PC Board Repair Replace Power Supply Power LED ON OK air pressure LED ON air flows once torch trigger is pressed Torch doesn t strike the arc Fault...

Page 18: ...lo che appare sul prodotto o sulla confezione indica che il prodotto non deve essere smaltito assieme agli altri rifiuti domesti ci Gli utenti devono provvedere allo smaltimento delle apparecchiature...

Page 19: ...gettati in modo da pro teggere il collo e il viso anche lateralmente dalla luminosit dell arco elettrico abbaglia Occorre mantenere sempre pulito il filtro co lorato vetro inattinico se rotto o deteri...

Page 20: ...concentrazioni di inquinanti non superino i valori limiti consentiti Fig 6 inoltre ogni procedimento di saldatura e taglio deve essere eseguito su superfici metalliche prive di ruggine e di vernice al...

Page 21: ...n la sua potenza massima e la sua tensione di alimen tazione vedi targa dati e conformi alle norme e regolamenti in vigore Il collegamento monofase o trifase con terra filo giallo verde venga eseguito...

Page 22: ...uscita del ge neratore mantenendoli il piu vicino possibile tra di loro e stesi sul pavimento 3 Richiudendo in modo corretto tutti i pannelli del generatore dopo aver eseguito un operazione di manute...

Page 23: ...t A temperature comprese tra 0 e 40 C In luoghi protetti da olio vapore e gas corrosivi In luoghi non soggetti a particolari vibrazioni o scosse In luoghi protetti dai raggi del sole e dalla pioggia A...

Page 24: ...one o di saldatura danneggiati La torcia di saldatura non deve mai essere puntata contro l operatore o un altra perso na Il generatore non deve mai essere utilizzato senza i suoi pannelli di copertura...

Page 25: ...iche tecniche del banco da taglio prima di procedere Di default la riduzione della tensione di uscita pari a 1 50 Nel caso il banco di taglio da collegare ri chiedesse una tensione diversa possibile i...

Page 26: ...taglio impostata durante l arco pilota visualizza la corrente di arco pilota e durante il taglio la corrente di taglio Premendo il tasto di spurgo aria B il display visua lizza il valore regolato in...

Page 27: ...D verde OK ON pressione aria corretta Figura 15 A B C E D H G F LED rosso Increase ON pressione aria troppo bassa LED rosso Decrease ON pressione aria troppo alta D LED corrente di taglio Si accende q...

Page 28: ...6 Collegare alla rete e posizionare l interruttore principale in posizione ON per fornire tensio ne al sistema CAVO DI MASSA Assicurarsi che ci sia una buna connessione del cavo di massa al pezzo da t...

Page 29: ...sto di selezione A nel pannello di controllo Tenere la torcia con la punta della torcia a 1 5 mm dal pezzo Tenere la torcia ad un angolo di 45 con il pezzo in lavorazione Premere il pulsante tor cia p...

Page 30: ...montaggio dei compo nenti della torcia inverso rispetto allo smon taggio Fate attenzione che l anello distributore ven ga montato nel verso corretto Rimontare l ugello avvitandolo manualmente forzando...

Page 31: ...nnesco dell arco pilota in aria torcia non assemblata correttamente punta della torcia a contatto con il pezzo componenti della testa della torcia mancanti o danneggiati ricambi non originali RICERCA...

Page 32: ...difettoso Fare riferimento al paragrafo manutenzione parti della torcia Scheda difettosa Riparare sostituire il generatore LED di rete ON LED OK della pressione dell aria acceso gas scorre La torcia...

Page 33: ...2 3 8 12 15 2 3 10 9 12 16 1 3 7 6 5 11 14 Electrode Tip Swirl ring Retaining cap Shield cap Elettrodo Cappa Diffusore Boccola Distanziale Starter KIT 105 125 A Starter KIT 160 A Cutting 45 85 A Goug...

Page 34: ...IT 105 A 23015477BH Starter kit includes Electrode Tip Swirl ring Retaining cap Shield cap Elettrodo Cappa Diffusore Boccola Distanziale CONSUMABLES Pos 1 23015447BH 2 23015460BH 3 23015448BH 4 230154...

Page 35: ...Shield cap 30 Shield cap Contact Cutting 80 100 A Long Cont Cut 30 70 A Long Cont Cut 80 100 A Gouging 100 A Cutting 20 70 A Contact Cutting 20 70 A Cutting 80 100 A 70 A 6 pin 6m 23010157 1 1 1 3 3...

Page 36: ...77612041...

Reviews: