14 Helvar 458/CTR8 8-Channel Ballast Controller Module: Installation and User Guide
LCD timeout
When the LCD timeout is on, after 60 seconds of inactivity on the Control Panel, the back-light on the
Control Panel LCD Display dims down and the Control Panel is then in standby mode.
Options:
Timeout:
✓ (up button);
x
(down button)
(Default: ✓ = yes)
Factory reset
Reset the module to the original settings (defaults).
Note:
Restoring factory settings returns all connected lighting to default levels immediately.
Press and hold ‘OK’ for 10 seconds until a ‘✓ Done’ message appears.
Use password
Note:
The password is disabled by default.
You can use the factory-set password for the module.
If the password is enabled, you must enter the correct password; otherwise you can only use the following functions/
menus:
• Change output levels
• View technical information about the module
• Recall a scene
• Enter the password
If you chose to use the password, after one minute of inactivity the Control Panel goes to standby and the ‘Enter
password’ menu appears in ‘Main menu’.
‘Use password’ disables the functionality of the remaining menus. You can access the menus but cannot change any
settings unless you enter the password . The password is ‘58’ (without the quotation marks).
When you enter the menu, a key ( ) is displayed in the bottom right of the screen to indicate that you cannot enter any
settings.
Options:
Use password:
✓ (up button);
x
(down button)
(Default:
x
= no)
Press ‘OK’ to confirm the new selection, and a ‘✓ Done’ message appears.
The password lock will be applied after a period of 60 seconds from this message appearing.
Enter password
If the password is enabled and you want to use all the functions of the module, you must enter the correct password.