background image

  18 

Limited Warranty 

HELTUN warrants this product to be free from defects in workmanship or materials, under normal use and service, for 
a  period  of  one  (1)  year  from  the  date  of  purchase  by  the  consumer  ("Warranty  Period").  HELTUN  will  extend  this 
Warranty Period to three (3) years from the date of consumer purchase for any consumer who registers his/her product 
with HELTUN at this website page: bonus.heltun.com. This Limited Warranty applies only to the first end-user of the 
product and is not transferable. 
 
If during the Warranty Period the product is determined to be defective or malfunctions due to workmanship or materials, 
HELTUN, at HELTUN's option, shall either repair or replace the defective product. If the product is defective, (i) return 
it  with  dated  proof  of  purchase  to  the  place  it  was  purchased;  or  (ii)  contact  HELTUN  Customer  Care  by  email  at 
[email protected]. HELTUN Customer Care will make the determination whether the product should be returned or 
whether a replacement product will be sent to you. 
 
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THIS LIMITED WARRANTY IS IN LIEU OF 
ALL  OTHER  COVENANTS  AND  WARRANTIES,  EITHER  EXPRESS  OR  IMPLIED,  INCLUDING  WITHOUT 
LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE, 
OR NON-INFRINGEMENT. HELTUN MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. 
 
THIS  LIMITED  WARRANTY  DOES  NOT  COVER  REMOVAL  OR  REINSTALLATION  COSTS.  THIS  LIMITED 
WARRANTY  SHALL  NOT  APPLY  IF  IT  IS  SHOWN  BY  HELTUN  THAT  THE  DEFECT  OR  MALFUNCTION  WAS 
CAUSED BY DAMAGE DONE BY A CONSUMER INCLUDING DURING INSTALLATION. THIS LIMITED WARRANTY 
IS VOID IF DEFECT(S) RESULT FROM A FAILURE TO HAVE THIS PRODUCT INSTALLED PROPERLY. 
 
HELTUN'S SOLE RESPONSIBILITY AND THE CONSUMER'S SOLE REMEDY UNDER THIS LIMITED WARRANTY 
SHALL BE TO REPAIR OR REPLACE THE PRODUCT WITHIN THE TERMS STATED ABOVE. HELTUN SHALL NOT 
BE  LIABLE  FOR  ANY  LOSS  OR  DAMAGE  OF  ANY  KIND,  INCLUDING  ANY  INCIDENTAL  OR  CONSEQUENTIAL 
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR 
IMPLIED,  OR  ANY  OTHER  FAILURE  OF  THIS  PRODUCT.  IN  NO  EVENT  SHALL  HELTUN'S  LIABILITY  EXCEED 
THE AMOUNT ACTUALLY PAID FOR THE PRODUCT WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED 
ON WARRANTY, TORT, OR CONTRACT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN EFFECT EVEN 
IF HELTUN WAS ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. 
 
SOME  JURISDICTIONS  DO  NOT  ALLOW  THE  EXCLUSION  OR  LIMITATION  OF  INCIDENTAL  OR 
CONSEQUENTIAL  DAMAGES,  SO  THIS  LIMITATION  MAY  NOT  APPLY  TO  YOU.  THIS  LIMITED  WARRANTY  IS 
THE ONLY EXPRESS WARRANTY HELTUN MAKES ON THIS PRODUCT.  
 
If you have any questions concerning this limited warranty, please write HELTUN Customer Care at [email protected]

 

HELTUN, INC. USA DELAWARE CORPORATION.

 

2/5 ARMENAKYAN STR., YEREVAN, 0047, ARMENIA

 

WWW.HELTUN.COM

 

[email protected]

 

Summary of Contents for HE-TPS04

Page 1: ...TOUCH PANEL SWITCH QUARTO HE TPS04 USER MANUAL for Hardware v 36 Firmware v 2 2...

Page 2: ...tions 8 Touch Panel Operation 9 Settings available through Z Wave network 10 Parameters List Factory Defaults 10 Z Wave Frequency 12 Hardware Software Versions 13 Power and Energy Consumption 13 Butto...

Page 3: ...10 backlight brightness levels can be configured manually or set to automatically adjust to ambient light conditions making them always easy to see Each button can be configured to control relay outp...

Page 4: ...a gateway or associated device Each button can trigger scenes Each button backlight can indicate a scene or associated device state Any channel may be excluded from control Nine modes for each button...

Page 5: ...agram Source 1 wire connect the required power source for relay 1 OUT 1 and relay 2 OUT 2 to the terminal labeled IN 1 3 Source 2 wire connect the required power source for relay 3 OUT 4 and relay 4 O...

Page 6: ...ss the two upper touch buttons and hold them for three seconds 3 All buttons will then sequentially blink blue red 4 If the inclusion has been successful all buttons will turn blue for three seconds 5...

Page 7: ...ay controller Z Wave Plus v2 Specifications Generic Device Class GENERIC_TYPE_WALL_CONTROLLER Specific Device Class SPECIFIC_TYPE_NOT_USED Supported Command Classes Command Class Version Required Secu...

Page 8: ...lue 0 commands to the associated devices Max supported nodes 1 Group 9 Touch 4 Multilevel Set is assigned to touch N4 It sends MULTILEVEL SWITCH command class frame when touch N4 was held Is used to s...

Page 9: ...settings 2 MOMENTARY REVERSED When the button is held the relay output is OFF as soon as the button is released the relay output state changes to ON see Parameters 41 44 settings 3 MOMENTARY TOGGLE W...

Page 10: ...t color for each state red for ON and blue for OFF or blue for ON and red for OFF see Parameter 30 settings If the HE TPS04 is included to the Z Wave gateway the scene controller light temperature hum...

Page 11: ...lick control mode for touch button 1 1 0 1 2 3 4 5 6 52 1 byte Click control mode for touch button 2 1 0 1 2 3 4 5 6 53 1 byte Click control mode for touch button 3 1 0 1 2 3 4 5 6 54 1 byte Click con...

Page 12: ...ion The HE TPS04 has Z Wave 700 series chip inside which allows to use the device in different Z Wave frequencies If there is a need to use the device in the frequency different from the factory defau...

Page 13: ...o the device outputs Using your connected device s power consumption specification see associated owner s manual set the load in Watts for Relay 1 OUT 1 in Parameter 12 Relay 2 OUT 2 in Parameter 13 R...

Page 14: ...arameters 31 34 Buttons Backlight Control Source 0 Backlight is disabled both color LEDs are turned off 1 Backlight is controlled by touch button reflects the button state 2 Backlight is controlled by...

Page 15: ...t relay and B is number of the second relay For example if the Parameter value is 24 or 42 it means the relays N2 and N4 will operate in inverse mode Relays can operate in an inverse mode in two diffe...

Page 16: ...ameter 142 Note It is not recommended to reduce the value of this Parameter in order not to increase the traffic on your network We recommend to reduce the value of this Parameter only in case of poor...

Page 17: ...or data will be sent to the gateway once even if the value of this Parameter is 0 Note It is not recommended to decrease the value of this Parameter in order not to increase the load on your Z Wave ne...

Page 18: ...R WARRANTIES EXPRESS OR IMPLIED THIS LIMITED WARRANTY DOES NOT COVER REMOVAL OR REINSTALLATION COSTS THIS LIMITED WARRANTY SHALL NOT APPLY IF IT IS SHOWN BY HELTUN THAT THE DEFECT OR MALFUNCTION WAS C...

Reviews: