background image

  11 

16 

Reserved by the manufacturer 

17 

1 byte 

Air Temperature Calibration in °C, value X 10, e.g. 1.0°C=10 

-

100 … 100 

18 

Reserved by the manufacturer 

19 

1 byte 

Time correction by controller 

0, 1 

20 

Reserved by the manufacturer 

21 

1 byte 

Week Day 

1, 2, 3, 4, 5, 6, 7 

22 

2 bytes 

Time: Hour and Minutes 

0 … 2359 

23-29 

Reserved by the manufacturer 

30 

1 byte 

Active state backlight color 

0, 1 

31 

1 byte 

Backlight 1 control source 

0, 1, 2 

32 

1 byte 

Backlight 2 control source 

0, 1, 2 

33 

1 byte 

Backlight 3 control source 

0, 1, 2 

34 

1 byte 

Backlight 4 control source 

0, 1, 2 

35-40 

Reserved by the manufacturer 

41 

1 byte 

Hold control mode for touch button 1 

0, 1, 2, 3, 4 

42 

1 byte 

Hold control mode for touch button 2 

0, 1, 2, 3, 4 

43 

1 byte 

Hold control mode for touch button 3 

0, 1, 2, 3, 4 

44 

1 byte 

Hold control mode for touch button 4 

0, 1, 2, 3, 4 

45-50 

Reserved by the manufacturer 

51 

1 byte 

Click control mode for touch button 1 

0, 1, 2, 3, 4, 5, 6 

52 

1 byte 

Click control mode for touch button 2 

0, 1, 2, 3, 4, 5, 6 

53 

1 byte 

Click control mode for touch button 3 

0, 1, 2, 3, 4, 5, 6 

54 

1 byte 

Click control mode for touch button 4 

0, 1, 2, 3, 4, 5, 6 

55-60 

Reserved by the manufacturer 

61 

1 byte 

Relay 1 control source 

0, 1, 2, 3, 4 

62 

1 byte 

Relay 2 control source 

0, 1, 2, 3, 4 

63 

1 byte 

Relay 3 control source 

0, 1, 2, 3, 4 

64 

1 byte 

Relay 4 control source 

0, 1, 2, 3, 4 

65-70 

Reserved by the manufacturer 

71 

2 bytes 

Timer mode duration for button 1 

0 to 43200 

72 

2 bytes 

Timer mode duration for button 2 

0 to 43200 

73 

2 bytes 

Timer mode duration for button 3 

0 to 43200 

74 

2 bytes 

Timer mode duration for button 4 

0 to 43200 

75-100 

Reserved by the manufacturer 

101 

1 byte 

Group 1 relay inverse mode 

0, 12, 13, 14, 21, 

23, 24, 31, 32, 34, 

41, 42, 43 

102 

1 byte 

Group 2 relay inverse mode 

0, 12, 13, 14, 21, 

23, 24, 31, 32, 34, 

41, 42, 43 

103-110 

Reserved by the manufacturer 

111 

4 bytes 

Relay control scenario 1 

0, 10000000 to 

43112359 

112 

4 bytes 

Relay control scenario 2 

0, 10000000 to 

43112359 

Summary of Contents for HE-TPS04

Page 1: ...TOUCH PANEL SWITCH QUARTO HE TPS04 USER MANUAL for Hardware v 36 Firmware v 2 2...

Page 2: ...tions 8 Touch Panel Operation 9 Settings available through Z Wave network 10 Parameters List Factory Defaults 10 Z Wave Frequency 12 Hardware Software Versions 13 Power and Energy Consumption 13 Butto...

Page 3: ...10 backlight brightness levels can be configured manually or set to automatically adjust to ambient light conditions making them always easy to see Each button can be configured to control relay outp...

Page 4: ...a gateway or associated device Each button can trigger scenes Each button backlight can indicate a scene or associated device state Any channel may be excluded from control Nine modes for each button...

Page 5: ...agram Source 1 wire connect the required power source for relay 1 OUT 1 and relay 2 OUT 2 to the terminal labeled IN 1 3 Source 2 wire connect the required power source for relay 3 OUT 4 and relay 4 O...

Page 6: ...ss the two upper touch buttons and hold them for three seconds 3 All buttons will then sequentially blink blue red 4 If the inclusion has been successful all buttons will turn blue for three seconds 5...

Page 7: ...ay controller Z Wave Plus v2 Specifications Generic Device Class GENERIC_TYPE_WALL_CONTROLLER Specific Device Class SPECIFIC_TYPE_NOT_USED Supported Command Classes Command Class Version Required Secu...

Page 8: ...lue 0 commands to the associated devices Max supported nodes 1 Group 9 Touch 4 Multilevel Set is assigned to touch N4 It sends MULTILEVEL SWITCH command class frame when touch N4 was held Is used to s...

Page 9: ...settings 2 MOMENTARY REVERSED When the button is held the relay output is OFF as soon as the button is released the relay output state changes to ON see Parameters 41 44 settings 3 MOMENTARY TOGGLE W...

Page 10: ...t color for each state red for ON and blue for OFF or blue for ON and red for OFF see Parameter 30 settings If the HE TPS04 is included to the Z Wave gateway the scene controller light temperature hum...

Page 11: ...lick control mode for touch button 1 1 0 1 2 3 4 5 6 52 1 byte Click control mode for touch button 2 1 0 1 2 3 4 5 6 53 1 byte Click control mode for touch button 3 1 0 1 2 3 4 5 6 54 1 byte Click con...

Page 12: ...ion The HE TPS04 has Z Wave 700 series chip inside which allows to use the device in different Z Wave frequencies If there is a need to use the device in the frequency different from the factory defau...

Page 13: ...o the device outputs Using your connected device s power consumption specification see associated owner s manual set the load in Watts for Relay 1 OUT 1 in Parameter 12 Relay 2 OUT 2 in Parameter 13 R...

Page 14: ...arameters 31 34 Buttons Backlight Control Source 0 Backlight is disabled both color LEDs are turned off 1 Backlight is controlled by touch button reflects the button state 2 Backlight is controlled by...

Page 15: ...t relay and B is number of the second relay For example if the Parameter value is 24 or 42 it means the relays N2 and N4 will operate in inverse mode Relays can operate in an inverse mode in two diffe...

Page 16: ...ameter 142 Note It is not recommended to reduce the value of this Parameter in order not to increase the traffic on your network We recommend to reduce the value of this Parameter only in case of poor...

Page 17: ...or data will be sent to the gateway once even if the value of this Parameter is 0 Note It is not recommended to decrease the value of this Parameter in order not to increase the load on your Z Wave ne...

Page 18: ...R WARRANTIES EXPRESS OR IMPLIED THIS LIMITED WARRANTY DOES NOT COVER REMOVAL OR REINSTALLATION COSTS THIS LIMITED WARRANTY SHALL NOT APPLY IF IT IS SHOWN BY HELTUN THAT THE DEFECT OR MALFUNCTION WAS C...

Reviews: