74
Helmholz Modem 56k small/Modem 56k USB small
S13*
Number of dialing attempts to send the message
Bit Meaning
Bit 0 – 3
Number of dialing at-
tempts
Range of values:
1...12
Default value: 3
S13 determines the number of attempts to send
the message.
Note:
The limitation to a maximum of 12
attempts is necessary for approval
purposes (black listing).
Bit 4 - 7
Reserved
S14*
General settings
Bit
Meaning
Bit 0
Reserved
Bit 1
Echo on inputs
Command echo
0: Echo off
1: Echo on
Bit 2
Reserved
Bit 3
Result format
Result codes:
0: Message numbers
(
ATV0
)
1: Message texts (
ATV1
)
Bit 4
Reserved
Bit 5
Tone/pulse dialing
Tone/pulse
0: Tone dialing (
ATT
)
1: Pulse dialing (
ATP
)
Bit 6
Reserved
Bit 7
Originate/answer
Originate/answer 0:
Answer
mode
1:
Originate
mode
S15*
DTC Time Settings
The idle connection control is a function integrated in the firmware which monitors
the data transmission in online mode. This function prevents the modem to stay
online for an unlimited amount of time, although no data is being transmitted any-
more.
In the registry S15, any time period between 1 and 255 seconds may be entered. If S15
is set to 0, the idle connection control is switched off.
The timer will run immediately after the modem goes off-hook. As soon as the timer
has run out, a modem reset is performed (which will forcibly lead to the hanging up
of the modem).
S17*
Initial character for remote configuration
In S17, the ASCII code of a character which is used to start the remote configuration,
is defined. Values >127 switch the remote configuration off completely. The default
setting in S17 is “42”, which equals the ASCII character “*”. This means that the re-
mote configuration is started with the Escape character sequence
<Pause> **** <Pause>
.
Summary of Contents for Modem 56k small