Helmholz Modem 56k small/Modem 56k USB small
Register Function
Units
Range Default
S30
Time period until hang up due to silence
10 s
0-255
0
S31* General
settings
-
C2h
(194)
S36*
Reset of error logs
-
135
S38
Time period until forced hang up
s
0-255
20
S39* Flow
control
-
3
S40* General
settings
-
104
S41* General
settings
-
195
S46*
V.42bis Data Compression
-
138
S48*
V42bis Connection setup protocol
-
7
S86
Error event code
-
Read-only
S91* Transmit
Level
-
0-15 9
S95* Result
code
-
0
10.2
Description S Registry
Note:
Registries marked with *) are stored in the user defaults with the command
AT&W
-
Befehl.
S0*
Number of ringing tones until automatically going off-hook
Number of rings until the modem goes off-hook
For S0=0 the modem will not go off-hook when a call comes in. The value of S0 can be
between 0 and 5.
S1
Ringing tone counter
Counter for call ringing. S1 is read-only. S1 will be reset to zero, when the modem
answers a call.
S2*
Escape
Escape character which causes a switch from data mode to online command input
mode. Values larger than 127 will result in no ESC character being recognized.
S3
Return
Carriage Return Character (CR).