28
Helmholz Modem 56k small/Modem 56k USB small
5.6
Send Messages
Note:
The sending time of an SMS from the sender to a recipi-
ent depends on the pertinent provider of the service
number. Depending on the degree of utilization and
the time of day, an SMS may be on the way for an ex-
tended period.
5.6.1
Transmission Configuration
The modem can not only send the alarm message to another ana-
logue modem, but also to a mobile phone as an SMS. Currently
GSM900 and GSM1800, and SMS to fixed networks, fax and e-
mail.
The maximum text length is 160 characters.
Protocol settings – see table -
Transmission Protocol Data
format
Example
Data Connection
AT*M0
SMS to Mobile
PET
8N1
D1 or
E Network
AT*M1
SMS to Mobile
UCP
7E1
AT*M2
SMS to Mobile
PET
7E1
AT*M3
SMS to Mobile
UCP
8N1
D2 network
AT*M4
Fax
AT*M5
SMS to Mobile
or Fixed Network
AT*M6
Enter the service number of the network provider to send SMS, or
the phone number for fax and data connections
Definition of the collective message
Definition of the variable alarm texts and phone numbers to send
SMS (alarm text 1 or 2). After this command is activated, the mo-
dem will query the alarm text.
AT*M<n>
AT*V
AT&Z0=<phone num-
ber>
AT*V1
AT*V2