Appendix C
Setting Up HM1520 Module for CompactLogix
Adding HM1520 module to your RXLogix 5000 project file
Open the RSLogix 5000 project in which you wish to install the module.
Right click on I/O Configuration
Select New Module
Select 1769 MODULE – Generic 1769 Module
Click OK
Module Properties:
Enter Module name (must begin with a letter)
example) HELM HM1520
Enter Module description
Enter Slot location
Select Comm Format. Must be Data – INT
Connection Parameters
INPUT 101
8
OUTPUT 100 8
CONFIGURATION 102
0
I/O Data Tags for RSLogix 5000
INPUT IMAGE DATA TAGS
Data Tags
Local:x.I
Data
Type
Bit Description
.Data[0] BIT 0
1
2
3
4
5
6
7
8
9
Channel 1 High Capacity Alarm Indication Bit
Channel 1 Low Capacity Alarm Indication Bit
Channel 2 High Capacity Alarm Indication Bit
Channel 2 Low Capacity Alarm Indication Bit
Channel 1 High Trend Alarm
Channel 1 Low Trend Alarm
Channel 2 High Trend Alarm
Channel 2 Low Trend Alarm
Reserved
Learn Cycle Indication Bit
.Data[1]
INT
-
Channel 1 (Left) Load Value
.Data[2]
INT
-
Channel 2 (Right) Load Value
.Data[3]
INT
-
Channel 1 Percent Deviation Value
.Data[4]
INT
-
Channel 2 Percent Deviation Value
.Data[5]
INT
-
Channel 1 Sample Value in Tons
.Data[6]
INT
-
Channel 2 Sample Value in Tons
.Data[7] INT -
Sample
Count