background image

Features Include:

• Narrow vertical spread of +/- 3°

Multivolt

Capable (9-33volts)

Lamp Mounting Instructions:

• Lamp should not be exposed to high temperatures eg from exhaust, radiators etc.
• Lamp mounting surface should be vertical to the ground.
• Lamp must be mounted horizontally for optimum wide angle light distribution.
• Lamp should be unobstructed by any part of the vehicle.

Screw Cap Removal

Carefully insert a small flat blade screwdriver between the cap and
the lens and pull towards the lens, the cap will clip off.
To install the cap push in by hand until the top is flush with the lens.

Surface Mounting:

Drill two holes up to 6.5mm O at 148mm centres. 6mm O screws or bolts are
recommended to mount the lamp using the mounting bushes provided.
The lamp should be mounted on a flat surface.
• If passing the cable through a hole, ensure there are no sharp edges to cut or

chafe the cable. Alternatively, cable can be routed through the end of the base.

• Connect cable as per chart above.
• Try to keep the cable length as long as possible, preferably join the cable inside

a sealed cable junction box.

• Clip the screw caps on securely until flush with the lamp surface.

Note:

When mounting lamp units side by side

allow a gap of 5mm to ensure screw cap removal.

Wiring

Note:

Lamp is polarity conscious.

The reversal of the polarity will not damage this product but will
inhibit its function.

Warranty:

Hella branded products are covered by a warranty against
manufacturing or material defects. Lamp is sealed and does not
have any serviceable parts inside; opening the lamp will invalidate warranty.

Technical data

Colour

Connect to

Power Consumption

White

Negative (-)

Red

On (+)

9 watts

Blue

Flash (+)

9 watts maximum

Brown

Sync

Mounting
bush

Cable routing

Note:

Bolts not included

1 White ( – )

3 On ( + )

4 Flash ( + )

2 Sync ( + )

DT CONNECTOR VERSIONS
Hella P/N 959 850-00
Deutsch P/N DT04-4P

Hella shall be absolved from all
responsibility for any modifications
performed on the luminaire

Use only certified original equipment for
replacement purposes

Wide horizontal beam of +/- 15°

The On (red) cable is load dump protected by the transient voltage
suppressor. The flash (blue) and sync (brown) cables may be
permanently shorted to ground or to maximum operating voltage of 33
volts without damage to the circuit.

Page 2

for:

Part No. 2XD 959 037-xx

MOUNTING INSTRUCTIONS

DuraLed

®

Multi Flash

LED High Intensity Signal Lamp

Please retain for future reference

MOUNTING INSTRUCTIONS

for:

 

Part No. 959037xx

DuraLED

®

 Multi-Flash

 High Intensity Signal Lamp

Please retain for future reference

Reviews: