Operating Modes
Programming Mode (selecting a flash pattern)
Steady State:
Step by step instructions:
*Note: ensure that the other cable connections are not disturbed (white and red). If power is interrupted,
programming will need to be repeated from step 1 -
*Note connecting the flash (blue) cable to positive (+) will change the flash pattern off-set timing - please
see the section "
before using this feature.
Note:
Lamp operates as a continuous on signal
Lamp operates in the flash mode pre-selected by the user
Lamp operates in bursts of quad flashes (intended for emergency situations)
amp will flash twice then stay on (steady state)
.
Flash State:
Blitz State:
The programming mode allows the user to select one of the 10 available flash patterns (see fig. 1)
1. Connect On (red) cable to postive (+) and white cable to negative (-)
2. Connect flash (blue) cable to negative (-).
3. Connect sync cable (brown) to positive (+)
4. The flash (blue) cable & sync (brown) cable should now be disconnected
5. The previously selected flash pattern will now activate
.
6. Connect then disconnect the flash (blue) cable to negative (-) to cycle / select the next flash pattern as shown in fig. 1 below
7. Disconnect power from all cables for at least 10 seconds to save the currently selected flash pattern.
Lamp will automatically exit programming mode after approx. 65 seconds of inactivity on flash (blue) cable
Blitz mode (program 4) will start flashing
after approx 10 seconds the l
(factory supplied default is flash mode 1)
(When operating in flash
state the pattern selected will now be used)
if power was interrupted, blitz mode will activate each time flash
(blue) is connected to negative (-)
syncronise an array of lamps"
•
•
•
Cable connections
Cable Colour
Steady
Flash
Blitz
White
Neg (-)
Neg (-)
Neg (-)
Red
Pos (+)
Pos (+)
Pos (+)
Blue
*
Pos (+)
Neg (-)
Brown
*
*
*
Flash Pattern Timing (fig. 1)
Pattern
order
1
0
1 second
250ms
2
3
4
5
6
7
8
9
10
*Cable is isolated (not connected to positive (+) or negative (-))
500ms
750ms