Fensterventilator GX 225 und GX 300

Window fan GX 225 and GX 300

Ventilateur de fenêtre GX 225 et GX 300

N

N

1

L

L

ESA/U 1/3

1

2

5

7

4

6

BSX

ES..

L

L

1

N

N

1a

1

1b

Betrieb mit

Operation with on/off switch

Fonctionnement avec

commutateur

marche/arrêt

Ein/Aus-Schalter

Betrieb mit

Operation with speed

controller ES..

Fonctionnement avec

régulateur

élektronique ES..

Drehzahlsteller ES..

Betrieb mit

Operation with reversing

switch DSEL 2

Fonctionnement

avec

inverseur

DSEL 2

Wendeschalter DSEL 2

Betrieb mit

Operation with speed

controller/reversing

switch BSX

Fonctionnement avec

régulateur / inverseur BSX

Drehzahlsteller/Wendeschalter BSX

Betrieb mit

Operation with FR 22/30

Fonctionn. avec

régulateur /

inverseur

FR 22/30

Drehzahlsteller/Wendeschalter FR 22/30

92575 SS-538

Schalter intern / Internal switch

Commutateur interne

Belüftung / Intake air /

Introduction

B) = Belüftung / Intake / Intro.

L auf Klemme 1 anschließen

Connect L on terminal 1

Brancher L sur contacte 1

B) = Belüftung / Intake / Intro.

L auf Klemme 1 anschließen

Connect L on terminal 1

Brancher L sur contacte 1

B) = Belüftung / Intake / Intro.

L auf Klemme 1 anschließen

Connect L on terminal 1

Brancher L sur contacte 1

B) = Belüftung / Intake / Intro.

L auf Klemme 1 anschließen

Connect L on terminal 1

Brancher L sur contacte 1

Entlüftung / Extraction /

Extraction

A) = Entlüftung / Extraction

L auf Klemme 2 anschließen

Connect L on terminal 2

Brancher L sur contacte 2

A) = Entlüftung / Extraction

L auf Klemme 2 anschließen

Connect L on terminal 2

Brancher L sur contacte 2

A) = Entlüftung / Extraction

L auf Klemme 2 anschließen

Connect L on terminal 2

Brancher L sur contacte 2

A) = Entlüftung / Extraction

L auf Klemme 2 anschließen

Connect L on terminal 2

Brancher L sur contacte 2

nur Klappe / shutter only /

seulement le volet

Betrieb mit Klemme 1/2

Operation with terminal 1/2

Fonctionn. avec borne 1/2

Betrieb mit Klemme 1/2

Operation with terminal 1/2

Fonctionn. avec borne 1/2

Betrieb mit Klemme 1/2

Operation with terminal 1/2

Fonctionn. avec borne 1/2

Betrieb mit Klemme 1/2

Operation with terminal 1/2

Fonctionn. avec borne 1/2

A)

A)

A)

A)

B)

B)

B)

B)

Service und Information

D

HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen

F

HELIOS Ventilateurs · Le Carré des Aviateurs · 157 av. Charles Floquet · 93155 Le Blanc Mesnil Cedex

CH

HELIOS Ventilatoren AG · Steinackerstraße 36 · 8902 Urdorf / Zürich

GB

HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park ·

A

HELIOS Ventilatoren · Postfach 854 · Siemensstraße 15 · 6023 Innsbruck

Colchester · Essex · CO4 9HZ

SS-538

Summary of Contents for gx 225

Page 1: ...ethod and manner of transportation Damages due to improper transportation storage or operation are not liable for warranty INSTALLING THE FAN These products are intended for connection to fixed wiring Check that the electrical rating shown on the fan matches the mains supply All installations must be supervised by a qualified elec trician Installations and wiring must conform to current regulation...

Page 2: ...wall Make sure that the centre of the hole is located at least 205 mm GX 225 or 250 mm GX 300 from the edges of the wall Check there are no buried pipes or cables in the wall or obstructions on the outside e g electricity gas water Mark on the wall the centre of the hole and drill right through Use this center hole to draw a circle with a dia meter as shown Fig 1 Cut the hole Do not cut right thro...

Page 3: ...e fan assembly to the inside of the wall so that the spigot is inserted into the wall duct Mark the positions of the two fixing holes in the top left and bottom right corners Remove the fan assembly drill the holes and insert anchor fixings appropriate to the type of wall Re position the cable and fan assembly as before and screw securely in place Do not overtighten screws Note For particularly di...

Page 4: ...sumption with data on the rating plate Test protective conductor connection Check sealing of the connection cable and clam ping of the cable wires Start operation only if protection against accidental contact with impeller is guaranteed Check air flow direction LOOKING AFTER YOUR FAN Cleaning recommended once a month Before cleaning isolate the fan on all poles from the mains supply Allow 30 sec f...

Page 5: ...reverse switch GX 225 Spacer Frame single glasing DR 225 Order ref 5115 Spacer Frame secondary glasing DW 225 Order ref 5089 Wall Kit for wall installation KR 225 Order ref 5092 Ladder strips SB 50 3 Order ref 1386 GX 300 Spacer Frame single glasing DR 300 Order ref 5116 Spacer Frame secondary glasing DW 300 Order ref 5090 Wall Kit for wall installation KR 300 Order ref 5093 Ladder strips SB 50 4 ...

Page 6: ...Fensterventilator GX 225 und GX 300 Window fan GX 225 and GX 300 Ventilateur de fenêtre GX 225 et GX 300 Fig 1 GX 225 Fig 2 GX 225 Fig 1 GX 300 Fig 2 GX 300 Fig 5 Fig 3 Fig 4 Fig 6 Fig 8 Fig 7 6 ...

Page 7: ... Backdraugt shutter C Fan assembly D Inner clamp plate E Outer clamp plate grille F Ladder strips G Connector plate H Rating plate J Selector switch K Impeller A Grille Intérieure B Volet de Fermeture Anti refoulement C Ensemble Extracteur D Bride de Plaque Intérieure E Bride de Plaque Grille Extérieure F Colliers Métalliques Serflex G Plaque Raccord H Plaque Signalétique J Commutateur Sélecteur K...

Page 8: ...ancher L sur contacte 1 B Belüftung Intake Intro L auf Klemme 1 anschließen Connect L on terminal 1 Brancher L sur contacte 1 Entlüftung Extraction Extraction A Entlüftung Extraction L auf Klemme 2 anschließen Connect L on terminal 2 Brancher L sur contacte 2 A Entlüftung Extraction L auf Klemme 2 anschließen Connect L on terminal 2 Brancher L sur contacte 2 A Entlüftung Extraction L auf Klemme 2 ...

Reviews: