- 75 -
Revision 4.6 3/2004
DIMENSIONS
PRODUCT SPECIFICATIONS*
*5
10
15
20
25
30
50
60
100
150
200
250
300
500
600
1000
1500
2000
2500
3000
5000
6000
7500
10,000
vacuum
5
10
15
compound
±5
±10
±15
–15/+30
–15/+60
* Non-isolated, for clean dry gas only
0.25*
0.5*
1.0*
2.0*
3.0*
5.0*
10*
15*
25*
50*
100*
150*
200*
psi
in. H
2
O
in. Hg
ftSW
Bar
mBar
kPa
mPa
mmHg
cmH
2
O
mmH
2
O
kg/cm
2
User Selectable
**
Note: Engineering units identifi ed above are
accessible through the unit select feature.
However, readout will default to the pri-
mary unit of measure on start-up. Sensor
modules scaled in primary units other
than in. H
2
O (GQS-1) or psi (GQS-2) are also
available.
Consult factory.
±0.125*
±0.25*
±0.5*
±1.0*
±1.5*
±2.5*
±5.0*
±7.5*
±12.5*
±25*
±50*
±75*
±100*
STANDARD RANGES
GQS-2
GQS-1
GQS-2
GQS-1
psi
˝H
psi
˝H
2
O
(gauge and
(gauge/
Other Engineering Units**
(gauge and
(gauge/
Other Engineering Units**
(gauge and
(gauge/
Other Engineering Units**
absolute
differential
absolute
differential
pressure)
pressure)
pressure)
pressure)
PTE-1
3.25
7.88
.43/.58
1.73
3.25
PTE-1
PTE-1
PTE-1
Summary of Contents for PTE-1