14 Parameter Description
KRONOS 20
89
14.4
List 3: Functions
No. Name
Signification
4050 SpeedVarDetectOn
Level:
4
Range:
0..1
Page(s):
Activation of speed variance detection
4055 MisfireWarnCurveOn
Level:
4
Range:
0..1
Page(s):
Activation of warning curve for monitoring of misfiring
4056 MisfireEcyCurveOn
Level:
4
Range:
0..1
Page(s):
Activation of emergency curve for monitoring of
misfiring
4319 SubstOrLastStepprPos
Level:
4
Range:
0..1
Page(s):
Selection of stepper motor substitute position in case of
emergency alarm by fatal error
0 = last valid value
1 = substitute value (319
StepperPosSubst
)
4810 StopImpulseOrSwitch
Level:
6
Range:
0..1
Page(s):
Selection of type of engine stop switch
0 = Stop active only while stop command is applied
1 = Stop active by one single switch pulse until engine
stops
4811 StopOpenOrClose
Level:
6
Range:
0..1
Page(s):
Switch function „engine stop“ is active if switch is
0 = opened
1 = closed
5012 SubstOrLastMnfldPres
Level:
4
Range:
0..1
Page(s):
Selection of a substitute value for manifold pressure in
case of failure
0 = last valid value
1 = substitute value (1012
SubstMnfldPressure
)
5013 SubstOrLastMnfldTemp
Level:
4
Range:
0..1
Page(s):
Selection of a substitute value for manifold temperature
in case of failure
0 = last valid value
1 = substitute value (1013
SubstManifoldTemp
)
5014 SubstOrLastMeasPower
Level:
4
Range:
0..1
Page(s):
Selection of a substitute value for measured power in
case of failure
0 = last valid value
1 = substitute value (1014
SubstMeasuredPower
)
5015 SubstOrLastLambda
Level:
4
Range:
0..1
Page(s):
Selection of a substitute value for lambda sensor in case
of failure
0 = last valid value
1 = substitute value (1015
SubstLambda
)