![Heinzmann E-LES 30 Manual Download Page 18](http://html1.mh-extra.com/html/heinzmann/e-les-30/e-les-30_manual_2120026018.webp)
3 Sensors
10
KRONOS 20
3
Sensors
3.1
Overview Table
Sensor Speed
Intake Mani-
fold Pressure
Intake Manifold
Temperature
λ
Sensor
(optional)
HZM name
IA ..
P/T-S-01
LSM 11
Connection
SV 6-IA-2K
2 pin
Pressure sensor connector 4 pins
Measuring
methods
inductive,
active
piezo resistance,
active
NTC, passive
electrochemical
Measuring range
50..9,000 Hz
0.2..3.0 bar abs.
-40 to +130°C
1.00..2.00
Power supply
range
4.5..5.5 V DC
12..13 V AC/DC
Output signal
range
0..10 V AC
0.3..4.8 V
0..50 kOhm
0..900 mV
Operating tem-
perature range
-8 to +120°C
-40 to + 130°C
up to + 800°C
In order to allow sufficient flexibility and comparability of sensors, the min./max. values of
pressure sensors and temperature sensors are programmable.
3.2
Speed Pickup IA…
3.2.1
Technical Data
Operating principle
inductive sensor
Distance from measuring wheel
0.5 to 0.8 mm
Output
0 V to 12 V AC
Signal type
sine (depending from tooth shape)
Resistance approx.
52
Ohm
Temperature range
housing
-8°C to +120°C
cable
-5°C to +80°C
Protection grade
IP 55
Vibration
< 10g, 10 to 100 Hz
Shock
< 50g, 11 ms half sine
Connector used
SV 6 - IA - 2K (EDV-No: 010-02-170-00)