![Heinzmann E-LES 30 Manual Download Page 43](http://html1.mh-extra.com/html/heinzmann/e-les-30/e-les-30_manual_2120026043.webp)
6 Electric Connection
KRONOS 20
35
6.2
Cable Harness
W1
Battery
E-LES
Temperature- / Pressure Sensor
Magnetic Pickup
Closed Loop Input
Digital Inputs
Error Indicators
Communication
W2
W3
W4
W6
W7
W10
+
-
M
Control Unit
KRONOS 20
W5
Figure 19: Cable designations
W 1 power supply
max. length 15 m
2 x 1.50 mm²
W 2 gas valve control
max. length 15 m
4 x 0.75 mm²
W 3 pressure / temperature sensor
max. length 15 m
4 x 0.75 mm²
W 4 speed pickup
2 x 0.75 mm²
W 5 actual power signal or
λ
-sensor signal
max. length 15 m
2/4 x 0.75 mm²
W 6 motor stop switch
1 x 0.75 mm²
(the switch must be powered with +24V)
W 7 error message
1 x 0.75 mm²
(the switch must be powered with +24V)
W 10 communication
max. 20 m
(at 9600 baud)
4 x 0.14 mm²