Heinrichs Messtechnik GmbH
Ex- Supplement operating manual
UMC4 with TM/TMU/TME/TMR/TM-SH
Page
17 of 31
4.5.4.3
Sensor circuits type of protection Ex ia II
Exciter circuit, terminals 9 (grey) and 10 (pink)
Linear output characteristic
Voltage
Uo
DC
12,5
V
Current
Io
90
mA
Power
Po
271
mW
Type of protection Ex ia IIC
Max. external inductance
Lo
5
mH
Max. external capacitance
Co
1320
nF
Type of protection Ex ia IIB
Max. external inductance
Lo
18
mH
Max. external capacitance
Co
8400
nF
Temperature sensor circuit, terminals 5 (purple), 6 (red), 7(blue), 8(black)
Voltage
Uo
DC
12,15
V
Current
Io
3,84 mA
Power
Po
12
mW
Linear output characteristic
Type of protection Ex ia IIC
Max. external inductance
Lo
1000
mH
Max. external capacitance
Co
1305
nF
Type of protection Ex ia IIB
Max. external inductance
Lo
1000
mH
Max. external capacitance
Co
8385
nF
Sensor circuits, (terminals, 1(brown) - 2(white) and 3(green)
–
4(yellow))
Values for each circuit
Voltage
Uo
DC
12,15
V
Current
Io
16
mA
Power
Po
47
mW
Linear output characteristic
Type of protection Ex ia IIC
Max. external inductance
Lo
140
mH
Max. external capacitance
Co
1305
nF
Type of protection Ex ia IIB
Max. external inductance
Lo
510
mH
Max. external capacitance
Co
8385
nF