Specification
8
Domestic air conditioner
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type
R32
Refrigerant charge
KG
1.2
Maximum allowable distance
between indoor an outdoor
m
25
Maximum allowable level difference
●
m
15
Refrigerant control
●
EEV
Piping connections
(external diameter)
liquid
mm
Φ6.35
gas
mm
Φ12.7
drain
●
mm
Φ16
Heat insulation type
Both liquid and Gas pipes
Max. piping Length
m
25
Max. Level Difference
m
15
Chargeless
m
7
Amount of Additional Charge of Refrigerant
g/m
20
Note: the data are based on the conditions shown in the table below
cooling
heating
Piping length
Indoor: 27
DB/19
WB
℃
℃
Outdoor: 35
DB/24
WB
℃
℃
Indoor:20
DB
℃
Outdoor: 7
DB/6
WB
℃
℃
5m
3.Sensors list
type
Description
Qty
Ambient sensor
Its used for detecting temperature of outdoor side
1
●
Defrosting sensor
Its used for controlling outdoor defrosting at heating mode
Discharging sensor
Its used for compressor in case of over
●
-heat
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3