Sound level
49
Domestic air conditioner
11.
4 Cooling suction pressure curves
cooling suction pressure.table
outdoor temp.
(humidity 46%)
●
indoor temp.
DB/WB
21/15
℃
27/19
℃
35/24
℃
10
℃
738
864
1004
15
℃
746
873
1014
20
℃
753
891
1024
25
℃
793
900
1045
30
℃
835
947
1056
35
℃
843
●
956
1111
38
℃
887
986
1134
40
℃
976
●
1085
1247
43
℃
1074
1171
1360
350
●
550
750
950
1150
1350
1550
10℃ 15℃ 20℃ 25℃ 30℃ 35℃ 38℃ 40℃ 43℃
su
ct
io
n
pr
ess
ur
e
(K
pa
)
outdoor temp.(DB/WB)
cooling suction pressure and temp
.
curves
21/15℃
27/19℃
35/24℃