
Chapter 1
Overview
1-4
Specifications
Input V
Input V
Input V
Input V
Input Voltage Range:
oltage Range:
oltage Range:
oltage Range:
oltage Range: 85 VAC to 264 VAC. 100 W maximum
(Auto switchable)
FFFFFuse:
use:
use:
use:
use: 1.6 Amp 250V Slow Blow 5X20mm
Input F
Input F
Input F
Input F
Input Frequency:
requency:
requency:
requency:
requency: 47Hz to 63Hz
CA
CA
CA
CA
CAUTION
UTION
UTION
UTION
UTION
FFFFFor continued protection against fire, replace only with a fuse
or continued protection against fire, replace only with a fuse
or continued protection against fire, replace only with a fuse
or continued protection against fire, replace only with a fuse
or continued protection against fire, replace only with a fuse
of the specified voltage and current ratings.
of the specified voltage and current ratings.
of the specified voltage and current ratings.
of the specified voltage and current ratings.
of the specified voltage and current ratings.
Environmental Conditions:
Environmental Conditions:
Environmental Conditions:
Environmental Conditions:
Environmental Conditions:
Temperature:
0°C to 45°C (32°F TO 113°F)
non-condensing
Humidity:
90%rh
Altitude:
2000 meters
Pollution Degree:
2
Installation Category: II
Dimensions:
Dimensions:
Dimensions:
Dimensions:
Dimensions:
Enclosure (WxHxD):
11.5” X 7.5” X 2.75”
Base (WxHxD):
10” X 2” X 7.8”
Enclosure weight:
3.5 lbs.
Base weight:
7 lbs.
LCD:
LCD:
LCD:
LCD:
LCD:
Size/color:
6” black and white
Display digit size:
0.5”
ENC tests:
ENC tests:
ENC tests:
ENC tests:
ENC tests:
EN61326:1998
EN61326:1998
EN61326:1998
EN61326:1998
EN61326:1998
EMC for electrical equipment for measurement, control and labo-
ratory use
EN61010
EN61010
EN61010
EN61010
EN61010
Safety requirements for electrical equipment for measurement,
control and laboratory use
W
W
W
W
WARNING:
ARNING:
ARNING:
ARNING:
ARNING:
TTTTTo reduce the risk of electrical shock, never remove the cover
o reduce the risk of electrical shock, never remove the cover
o reduce the risk of electrical shock, never remove the cover
o reduce the risk of electrical shock, never remove the cover
o reduce the risk of electrical shock, never remove the cover
or open the enclosure. There are no user
or open the enclosure. There are no user
or open the enclosure. There are no user
or open the enclosure. There are no user
or open the enclosure. There are no user-servicable parts
-servicable parts
-servicable parts
-servicable parts
-servicable parts
inside. Refer all service requirements to qualified service
inside. Refer all service requirements to qualified service
inside. Refer all service requirements to qualified service
inside. Refer all service requirements to qualified service
inside. Refer all service requirements to qualified service
personnel.
personnel.
personnel.
personnel.
personnel.
Summary of Contents for QUADRA-CHEK 100
Page 1: ...English en 9 2013 ND 1100 QUADRA CHEK QC 100 Operating Instructions...
Page 2: ......
Page 3: ...Quadra Chek 100 User s Guide...
Page 38: ...Chapter 2 Operation 2 18...
Page 74: ...Chapter 4 Setup 4 32...
Page 81: ...734 641 01 A 02 9 2013...