HEIDENHAIN ND 510 Manual Download Page 8

Rear Panel

Ground  terminal

Power switch

Inputs for HEIDENHAIN linear encoders

(ND 510: 2, ND 550: 3)

with sinusoidal output signals

(7µA

pp 

to 16 µA

pp

),

Connecting cable max. 20 m (66 ft),

Input frequency max. 50 kHz with

6 m/20 ft cable (35 kHz with 10 m/32.8 ft,

20 kHz with 20 m/66 ft)

X2

X1

X3

Interfaces X1, X2 and X3 comply with the recommendations in EN 50 178
for separation from line power.

281 615-23 · SW 246 119 02 · 10 · 6/99 · H · Printed in Germany · Subject to change without notice

56

±

0.2

2.204

±

.008"

93+2

3.66+.08"

29+0.5

1.14+.02"

20

.79"

0

21

±

0.2

1

±

.008"

209

±

0.2

8.228

±

.008"

230

±

0.2

9.055

±

.008"

92

3.622"

M4

43.3

1.704"

Installation

You can mount the display unit on a surface
using M4 screws, or on a tilting base from
HEIDENHAIN (Id.-Nr. 281 619 01).

Danger of electrical shock!

Unplug the power cable before opening the housing.
Connect a protective ground. This connection should never be interrupted.

Danger to internal components!

Do not engage or disengage any connections while the unit is under power.
Use only original replacement fuses.

Power Supply and Connection

Primary-clocked power supply.

Voltage range 

100 V to 240 V (–15% to +10 %) 

 Frequency 

48 Hz to 62 Hz

Power consumption 

ND510: 9 W, ND550: 12 W 

 Line fuse 

F 1 A (in unit)

Minimum cross-section of power cable: 0.75 mm

2

To increase the noise immunity, connect the ground terminal on the rear panel
to the central ground point of the machine. (Minimum cross-section 6 mm

2

)

Ambient Conditions

Temperature range

Operation: 0°C to +45°C (32°F to 113°F)
Storage: –30°C to +70°C (–32°F to 158°F)

Rel. humidity

Annual average: < 75%;  maximum: < 90%

Weight

2.3 kg

DR. JOHANNES HEIDENHAIN GmbH 

Dr.-Johannes-Heidenhain-Straße 5

D-83301 Traunreut,  Deutschland

      (0 86 69) 31-0 .        56 831
      (0 86 69) 50 61

FAX

FAX

     

 Service        

(0 86 69) 31-12 72

TNC-Service (0 86 69) 31-14 46
(0 86 69) 98 99

Summary of Contents for ND 510

Page 1: ...point 2 currently active SCL Scaling factor active Define workpiece edge as datum Blinking Waiting for operator to confirm selection Define centerline between two workpiece edges as datum Blinking Wai...

Page 2: ...ay shows the value last assigned to the reference mark position the REF indicator glows and the decimal point blinks Cross over the reference mark in each axis Move the axes one after the other until...

Page 3: ...sed on the new datum This function ends automatically Centerline between two workpiece edges as datum Select the datum Press the SPEC FCT key twice The indicator Centerline as datum starts blinking Pr...

Page 4: ...nput value SPEC FCT Select REF display ENT Save entry Exit compensation value table CL Delete entry Delete all compensation values Enter the parameters and compensation values as follows Display Entry...

Page 5: ...rect input value Input frequency too high for encoder input will occur for example when traverse speed too high Internal counter overflow Error while crossing over reference marks To clear the error m...

Page 6: ...ber Protected Operating Parameters In order to change protected operating parameters the code number 95 148 must be entered via P00 Code They remain accessible until the position display is switched o...

Page 7: ...with 2000 SP Distance coded with 5000 SP Encoder Monitoring off Alarm Off Encoder monitoring A Monitoring on Alarm On Axis display A Display measured position Axis Do not display measured position no...

Page 8: ...le before opening the housing Connect a protective ground This connection should never be interrupted Danger to internal components Do not engage or disengage any connections while the unit is under p...

Reviews: