Numeric keypad
and decimal point

Sign

• Change parameter

Confirm
entry values

Call operating
parameters

• Page forward in

parameter list

Datum setting
function

Status indicators

Select datum

• Page backward in

parameter list

Indicator

Meaning

REF

Reference mark was crossed over – datum points are now stored
in non-volatile memory.

Blinking:

 Waiting for reference mark to be crossed over.

in.

Position values displayed in inches.

   

  /      

 2

Datum point 1  /  Datum point 2  currently active.

SCL

Scaling factor active.

Define workpiece edge as datum.

Blinking:

 Waiting for operator to confirm selection.

Define centerline between two workpiece edges as datum.

Blinking:

 Waiting for operator to confirm selection.

Clear entry

• CL plus two-digit number:

select parameter

• Clear parameter entry

Select coordinate axis

(Z-axis with ND 550 only)

• Select axis-based operating parameters

Actual value and input display

(7-segment LED,
8 decades and sign)
Downwards:  X-axis,  Y-axis,
ND 550 only: Z-axis

MOD

0

Y

X

HEIDENHAIN

3

6

5

4

2

1

ENT

8

7

9

Z

REF

1

2

CL

1

2

SPEC

FCT

SCL

in.

Working with the digital readouts

 ND 510         ND 550

HEIDENHAIN

Summary of Contents for ND 510

Page 1: ...point 2 currently active SCL Scaling factor active Define workpiece edge as datum Blinking Waiting for operator to confirm selection Define centerline between two workpiece edges as datum Blinking Wai...

Page 2: ...ay shows the value last assigned to the reference mark position the REF indicator glows and the decimal point blinks Cross over the reference mark in each axis Move the axes one after the other until...

Page 3: ...sed on the new datum This function ends automatically Centerline between two workpiece edges as datum Select the datum Press the SPEC FCT key twice The indicator Centerline as datum starts blinking Pr...

Page 4: ...nput value SPEC FCT Select REF display ENT Save entry Exit compensation value table CL Delete entry Delete all compensation values Enter the parameters and compensation values as follows Display Entry...

Page 5: ...rect input value Input frequency too high for encoder input will occur for example when traverse speed too high Internal counter overflow Error while crossing over reference marks To clear the error m...

Page 6: ...ber Protected Operating Parameters In order to change protected operating parameters the code number 95 148 must be entered via P00 Code They remain accessible until the position display is switched o...

Page 7: ...with 2000 SP Distance coded with 5000 SP Encoder Monitoring off Alarm Off Encoder monitoring A Monitoring on Alarm On Axis display A Display measured position Axis Do not display measured position no...

Page 8: ...le before opening the housing Connect a protective ground This connection should never be interrupted Danger to internal components Do not engage or disengage any connections while the unit is under p...