DESCRIPTION

1. 

laser sweep emission

2. 

laser sweep reception

3. 

LED-signal (4)

4. 

screw for position lock (2)

5. 

connector

6. 

protection cover

7. 

visible laser beam (3)

8. 

notch for tilt angle adjustment (2)

9. 

adjustable bracket

10.  cable conduit (4)

SYMBOLS

LED-SIGNAL

DETECTION LEDs

no detection

ERROR LED

POWER LED

detection

no error

error

no power

power

Caution!

Laser radiation

LED flashes quickly

LED flashes

LED is off

Remote control 

sequence

Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer. 

The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.

BUILDING AUTOMATION AND SECURITY

1.   Detection LED: relay 1 - field 1
2.   Detection LED: relay 2 - field 2
3.   Error LED
4.   Power LED

Factory values

Possible 

remote control 

adjustments

Alarm

LED flashes slowly

TIP!    All LEDs can be switched off and on again by remote control:

Summary of Contents for HD-LSS25

Page 1: ...1 HD LSS25 LASER SCANNER FOR EXHIBIT SECURITY AND BUILDING AUTOMATION EN User s Guide...

Page 2: ...Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The ma...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...ggers relay 1 Field 2 only curtain C1 active triggers relay 2 alarm During night time field 2 is active too and triggers relay 2 intrusion alarm PROTECTION OF WORKS OF ART WARNING ALARM DAY AND NIGHT...

Page 5: ...ing template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Position...

Page 6: ...sensor is changed on purpose or by accident No reference point is memorized no alarm in case of interference with sensor position Adjust the lateral position of the detection field Adjust the tilt an...

Page 7: ...t IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the detection field to avoid disturbances WIDTH field 2 field 1 HEIGHT no field WIDTH HEIGHT FIELD...

Page 8: ...th fields activate curtain only on field 1 activate curtain only on field 2 activate curtain on both fields EX All curtains active on both fields The distances between the curtains depend on the mount...

Page 9: ...AVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote contr...

Page 10: ...nexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object...

Page 11: ...e power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic i...