7
5
-
-
-
-
FIELD DIMENSIONS
3 s
max. 30 s
The teach-in can be launched either via remote control or via connecting
the white/red and white/blue wires.
Launch a teach-in:
•
after changing the sensor position
•
when new objects are added to or changed in the detection zone.
During teach-in, the sensor learns its surroundings and adapts the
detection field shape to these. Objects in the detection field will be cut out.
IMPORTANT
:
Test the good functioning of the installation before leaving the premises.
Stay outside of the detection field to avoid disturbances.
WIDTH
field 2 = field 1
HEIGHT
no field
WIDTH
HEIGHT
FIELD 1
FIELD 2
10.0 m
EXAMPLES
for a field width of 6.2 m
for a field height of 4.5 m
Wait for the sensor to learn its environment
or lock it by remote control.
TEACH-IN
0.1 m - 25.0 m
10.0 m
10.0 m
10.0 m
To launch a teach-in via input, please contact heddier electronic for more information.
To launch a teach-in via remote control, use the following sequence:
no field
0.1 m - 25.0 m
0.1 m - 25.0 m