background image

11

heddier electronic GmbH | Pascherhook 34 - 48683 Coesfeld | Germany

T +49 (0) 25 46 911-0 | F +49 (0) +25 46 911-29 | [email protected] | www.human-detector.com

Technology:
Detection mode:
Detection range:

Angular resolution:
Min. detected object size (typ.):

Emission characteristics:
     IR laser:
     Red visible laser:
Supply voltage:
Power consumption:
Peak current at power-on:
Cable length:
Response time:
Output:
     Max. switching voltage:
     Max. switching current:
     Switching time:
     Output resistance:
     Voltage drop on output:
     Leakage current:
Input:
     Max. contact voltage:  
     Voltage threshold:
Response time monitoring input:
LED-signal:

Dimensions:
Material:
Colour:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screens:
Norm conformity:

laser scanner, time-of-flight measurement
movement and presence
default: 10 m x 10 m @ 2% remission factor*
max: 25 m x 25 m
0.3516 °
2.1 cm @ 3 m; 3.5 cm @ 5 m; 7 cm @ 10 m;  17.5 cm @ 25 m
(in proportion to object distance)

wavelength 905 nm; max. output pulse power 75 W (CLASS 1)
wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)
10-35 V DC @ sensor side 
< 5 W
1.8 A (max. 80 ms @ 35 V)
10 m
typ 20 ms; max. 80 ms (+ output activation delay)
2 electronic relays (galvanic isolated - polarity free)
35 V DC / 24 V AC
80 mA (resistive)
t

ON

=5 ms; t

OFF

=5 ms

typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA
2 optocouplers (galvanic isolated - polarity free)
30 V DC (over-voltage protected)
Log. H: >8 V DC; Log. L: <3 V DC
< 5 ms
1 blue LED: power-on status
1 orange LED: error status
2 bi-coloured LEDs: detection/output status 

(green: no detection; red: detection)

125 mm (D) x 93 mm (W) x 70 mm (H) (mounting b 14 mm)
PC/ASA
black or white
-45 °, 0 °, 45 °
-5 ° to +5 ° (lockable)
-3 ° to +3 °
IP65
-30 °C to +60 °C if powered; -10 °C to +60 °C unpowered
0-95 % non-condensing
< 2 G 
max. 30 %; homogenous
EN 60529; IEC 60825-1 Laser Class 1 & 3R; EN 60950-1; EN 50581
EN 61000-6-2 EMC - Industrial level
EN 61000-6-3 EMC - Commercial level

TECHNICAL SPECIFICATIONS

Specifications are subject to changes without prior notice.

All values measured in specific conditions.

*For other options, please contact heddier electronic

heddier electronic hereby declares that the HD-LSS25 is in conformity with the basic requirements and the other relevant provisions of the directives 
2014/30/EU, 2014/35/EU and 2011/65/EU.

Summary of Contents for HD-LSS25

Page 1: ...1 HD LSS25 LASER SCANNER FOR EXHIBIT SECURITY AND BUILDING AUTOMATION EN User s Guide...

Page 2: ...Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The ma...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...ggers relay 1 Field 2 only curtain C1 active triggers relay 2 alarm During night time field 2 is active too and triggers relay 2 intrusion alarm PROTECTION OF WORKS OF ART WARNING ALARM DAY AND NIGHT...

Page 5: ...ing template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Position...

Page 6: ...sensor is changed on purpose or by accident No reference point is memorized no alarm in case of interference with sensor position Adjust the lateral position of the detection field Adjust the tilt an...

Page 7: ...t IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the detection field to avoid disturbances WIDTH field 2 field 1 HEIGHT no field WIDTH HEIGHT FIELD...

Page 8: ...th fields activate curtain only on field 1 activate curtain only on field 2 activate curtain on both fields EX All curtains active on both fields The distances between the curtains depend on the mount...

Page 9: ...AVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote contr...

Page 10: ...nexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object...

Page 11: ...e power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic i...

Reviews: