background image

8

R1 R2

5

10

20

40

cm

R1

R2

R1

R2

cm

10

15

20

25

5

A - NO

P - NC

A - NO

P - NC

P - NC

A - NO

P - NC

A - NO

ms

100

200

300

400

500

600

700

800

900

X

X

X

X

REMOTE CONTROL ADJUSTMENTS (OPTIONAL)

FACTORY VALUES

IMMUNITY FILTER

MIN. OBJECT SIZE

OUTPUT CONFIGURATION

DETECTION FIELD 

REDIRECTION

approximate values

A = active

P = passive

NO = normally open

NC = normally closed

UNCOVERED ZONE

field 1

field 2

field 2

field 1 or 

field 2

off

indoor outdoor

low

outdoor

med

outdoor

high

indoor outdoor

low

outdoor

med

outdoor

high

CURTAIN

    C1   C2     C3    C4

DETECTION CURTAINS

deactivate curtain on both fields

activate curtain only on field 1

activate curtain only on field 2

activate curtain on both fields

EX:

All curtains active on both fields

The distances between the curtains depend on the mounting height and side. When mounted on the left, the distance between the first 

and the last curtain is approximately 10 cm for every meter (mounting height). Example: at 5 m the distance is 50 cm.

C1
C2
C3
C4

C1 + C2 active on field 1 only

C3 + C4 active on field 2 only

C1 active on both fields

C2+C3 active on field 2 only

C4 deactivated

OUTPUT ACTIVATION DELAY 

The outputs are triggered after a constant 

detection time of x ms (ex. value 3= 300 ms).

Increased sensitive (detection of black 

objects, ...)

Increased immunity to rain, snow, fog...

approximate values

Rx= RELAY OUTPUT

off

Summary of Contents for HD-LSS25

Page 1: ...1 HD LSS25 LASER SCANNER FOR EXHIBIT SECURITY AND BUILDING AUTOMATION EN User s Guide...

Page 2: ...Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The ma...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...ggers relay 1 Field 2 only curtain C1 active triggers relay 2 alarm During night time field 2 is active too and triggers relay 2 intrusion alarm PROTECTION OF WORKS OF ART WARNING ALARM DAY AND NIGHT...

Page 5: ...ing template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Position...

Page 6: ...sensor is changed on purpose or by accident No reference point is memorized no alarm in case of interference with sensor position Adjust the lateral position of the detection field Adjust the tilt an...

Page 7: ...t IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the detection field to avoid disturbances WIDTH field 2 field 1 HEIGHT no field WIDTH HEIGHT FIELD...

Page 8: ...th fields activate curtain only on field 1 activate curtain only on field 2 activate curtain on both fields EX All curtains active on both fields The distances between the curtains depend on the mount...

Page 9: ...AVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote contr...

Page 10: ...nexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any object...

Page 11: ...e power 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic i...

Reviews: