Please note that it is imperative to avoid tensile force on the connection cables. 

  

Please  note  that  only  the  manufacturer’s  connectors  may  be  connected.  Even 
“compatible”  connectors  can  loosen  the  connection  and  cause  an  electric  arc.  This  is 
especially important to consider when using power optimizers! 

 

Any change in the connector socket can lead to the warranty being rendered null and 
void, and therefore may only be carried out by trained and skilled personnel.  

 

No damaged modules may be installed! 

 

Both external connector sockets are fitted with a cable (1150 mm in length) and connectors. The socket (+) is located 
on the right-hand side, and the plug on the left-hand side (-). (Figure 4) The connectors are each designed in such a 
way as not to create confusion.  

       

               

Figure 4: Configuration of the connector sockets 

 

 

The individual solar modules in a string can be interconnected effortlessly.  

 

Please ensure the correct connection of the plugs and sockets! 

 

 

 

 

  

Figure  5: 

Connected MC4 modules 

 

The string cables are connected to the MC4 connectors on the first or last module in the string. 

Summary of Contents for NeMo 3.0

Page 1: ...Installation and operating manual www heckert solar com Status 08 2021...

Page 2: ...ny time without prior notice Please use the most current copy You can find this on our homepage under http www heckertsolar com de downloads partner download center montage html This installation and...

Page 3: ...veral hours Rear ventilation The output of solar modules decreases considerably as the modules heat up Rear ventilation avoids yield impairing heat accumulation The so called chimney effect draught be...

Page 4: ...e modules in their packaging until ready for installation Always set the pallets on a reinforced level ground and do not stack them under any circumstances Standard packaging Picking packaging Number...

Page 5: ...ease observe the specific instructions for handling solar modules with AR glass Compared with non coated glass the surface of AR glass has a similar resistance to mechanical or chemical influences and...

Page 6: ...llation situation and the system used Please observe the installation situations in the following table and the resulting maximum load capacity of the modules The values shown Figure 3 correspond to t...

Page 7: ...installation and to facilitate installation our module frames are fitted with holes for load restraints Screws with hexagon socket head caps are fixed in these holes in the module frame The screws are...

Page 8: ...trained and skilled personnel No damaged modules may be installed Both external connector sockets are fitted with a cable 1150 mm in length and connectors The socket is located on the right hand side...

Page 9: ...or to the inverter Please use solar cables that comply with the standard EN 50618 class 5 and the respective requirements The minimum cross section is 4mm Cable losses should be 1 At greater distances...

Page 10: ...lightning protection system in place or planned for the building the PV system must be integrated in the protection system against a direct lightning strike When using transformer less inverters due...

Page 11: ...nd service warranty Information and terms for our product and service warranties can be found on our homepage under www heckert solar com 9 Exclusion of liability These installation and operating inst...

Page 12: ...12 Excerpt from MC4 crimping instructions Multi contact source...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17 Heckert Solar GmbH Carl von Bach Stra e 11 D 09116 Chemnitz...

Reviews: