DEI-WKS-N
SWISS MADE
MODE
SET
Thank you for purchasing the Digital S-Line Indicator.
For proper operation, please read this manual thoroughly before use.
DIGITAL S-LINE INDICATOR
INSTRUCTION MANUAL
Model No. DEI-WKS-N
LCD Display
[SET] Button
Center (
“
Favorite
”
)
Button
Stem (Mounting Shaft)
Spindle
Contact Point
Display Rotates 270
°
Easy to read from any position.
Accessories
CR2032
CR2032 (Lithium Cell)
※
Included for test
Battery Cover
[MODE] Button
PARTS IDENTIFICATION
【
Power ON
】
Press [MODE], [SET], or Center Button to turn on power.
【
Power OFF, Sleep Mode
】
Press and Hold the [SET] button to enter Sleep Mode; continue
pressing to turn power OFF.
※
Sleep Mode is entered automatically if gauge is idles for about
20 min.
※
To exit Sleep Mode, press any button or move the Spindle.
※
When remaining battery level is low, the
『
』
icon is displayed;
please replace battery.
※
To reset all settings, press and hold [SET] and [MODE] at
same time for about 4 sec.,
“
”
will display.
B
[SET] Button
Sleep Mode
Power OFF
(Press and Hold)
(Press and Hold)
[SET] Button
mm
1
mm
POWER
BATTERY REPLACEMENT
①
Remove the (2x) battery screws using (+) PH#0 screwdriver.
Gently pry open the cover using a small standard screwdriver
in the notch and slide out the battery.
②
Insert the new battery following the polarity markings on the
cover.
③
Replace Battery Cover and tighten screws to secure.
CR2032
+
Notch
Battery
Battery Cover
Battery Cover
NOTICE
Use only CR2032 type battery.
Tolerance Setting capability
Calculation capability
Display rotates 270
°
Programmable
“
Favorite
”
Button
(Can be set for one touch access to frequently used functions.)
MIN
、
MAX
、
MINMAX (TIR) display functions
Direction of measurement (
+
/
−
) switchable
Preset function
Sleep mode (after approx. 20 min.)
Made in Switzerland
●
●
●
●
●
●
●
●
●
①
Mount indicator securely, such as on optional Magnetic Base,
and make sure that the Spindle is perpendicular to the
measurement surface.
②
Press [MODE], [SET], or Center Button to turn on power.
③
Check that the probe is in contact with surface, and refer to the
following to set the 0-Point.
FUNCTION SETUP:
“
Preset Value
”
Programmable
“
Favorite
”
Button:
“
Zero setting
”
LCD will display
“
0.000mm
”
or
“
0.0000mm
”
.
④
With Gauge body held fixed, and the probe in contact with the
workpiece, the LCD will display the difference between
workpiece and reference plane.
Refer to
Refer to
See Reverse for Feature Settings
→
FEATURES
SPECIFICATIONS
φ
8mm
140g
5
〜
40
℃
DEI-WKS-N
0.001mm/0.0001mm
(switchable)
0.5
μ
m
0-12.5mm
Less than 1.5N
2.3
μ
m
0.0001mm
CR2032 (Lithium cell)
×
1
Model No.
Measurement Range
Resolution
Displayed Resolution
Accuracy
Measurement Force
Repeatability
Mounting Shaft Diameter
Operating Temp. Range
Power Supply
Weight
Measured value is wrong
Clean measuring surfaces with
lens tissue or similar.
Confirm and re-set 0-Point setting.
●
●
LCD does not display
Displayed value is
unstable
Display is hard to read
●
●
●
Cycle power by removing and
replacing battery.
Replace battery with new one.
●
●
※
If problem persists, or if you have any questions, please contact distributor
or place of purchase.
※
Please note, manufacturer is unable to respond to inquires or provide
service directly. Please contact distributor or place of purchase.
Error Condition
Corrective Action
TROUBLESHOOTING
HOW TO USE