background image

 

Manual Explorer 15i 18i 2nd rev2.2 en   

Gecma Components electronic GmbH 

GEC17500221 

 

 

 

[email protected] 

+49 2273 9812 0   

 

 

 

 

 

Operating Manual 

Panel PC 

EXPLORER 15i / 18i 

2

nd

 Generation 

Doc: 60000206

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for EXPLORER 15i

Page 1: ...Manual Explorer 15i 18i 2nd rev2 2 en Gecma Components electronic GmbH GEC17500221 csckerpen eaton com 49 2273 9812 0 1 Operating Manual Panel PC EXPLORER 15i 18i 2nd Generation Doc 60000206...

Page 2: ...power supply input are increased safety and accessed via an Ex e terminal enclosure When the Explorer 15i 18i is correctly mounted into a min IP6X certificated housing with a cut out of 417mm x 328 5...

Page 3: ...cal connections can be seen in the wiring diagram 30100358 or 30100399 and the Ex certificate We recommend using CAT7 installation cable for the connection of the Ethernet interface X53 The Ethernet i...

Page 4: ...er is installed the max ambient temperature for the complete unit may be reduced when mounted in an additional housing To minimize external thermal load we recommend an all day shadowing of the device...

Page 5: ...at the BIOS the Explorer will start from CD DVD the installation CD has to be in the drive The standard installation process of Windows can be done now After completion the Windows installation we re...

Page 6: ...ble RLine 120 RS422 Ex e 4 wire default or auto TX up to 115 2K The manufacturer reserves the right to change technical data without notice in order to enhance the performance and take advantage of te...

Page 7: ...1500A Cable gland M12 for round cable Outer cable diameter 4 7mm 0 16 0 28 Recommended max cable length 15m 50ft f r RS232 Recommended max cable length 1000m 3300ft for RS485 422 Pay attention to the...

Page 8: ...ponding standards Mouse Interface X34 Terminal 1 6 Intrinsically safe ia Mini DIN 6pol Jack Ui 5 5V Ii not important Pi not important Li negligible Ci negligible Uo 5 5 V Io 71 mA Po 195 mW Lo 7mH Co...

Page 9: ...nding standards USB3i Interface X37 Terminal 1 4 Intrinsically safe ia USB Type A Jack Ui 5 5 V Ii not important Pi not importatnt Li negligible Ci negligible Uo 5 5 V Io 1 04 A Po 2 64 W Lo 40uH Co 5...

Page 10: ...ing standards COM2i Interface X40 Terminal 1 9 Intrinsically safe ia SUB D 9pol plug Ui 25 V Ii not important Pi not important Li negligible Ci negligible Uo 5 5 V Io 24 mA Po 32 mW Lo 50 mH Co 50 uF...

Page 11: ...sted in corresponding standards Mic Interface X44 Terminal 1 3 Intrinsically safe ia Stereo jack 3 5mm Ui 5 5 V Ii not important Pi not important Li negligible Ci negligible Uo 5 5 V Io 618 mA Po 852...

Page 12: ...not important Pi not important Li negligible Ci negligible Uo 5 4 V Io 420 mA Po 1 25 W Lo 0 15mH Co 50 uF Recommended max cable length 2m 6 5ft BS Interface X45 Terminal 1 2 Intrinsically safe ia Pho...

Page 13: ...cuit are integrated to supply optional other devices The Supply circuit and the Output circuit are connected parallel Serial Interface RS232 or RS485 or RS422 X51 Connection Significance RS232 RS485 R...

Page 14: ...Significance X34 1 Data X34 3 GND X34 4 UB X34 5 Clock Cable Screen GND USB1i Interface X35 Connection Significance X35 1 UB X35 2 D X35 3 D X35 4 GND Cable Screen GND USB2i Interface X36 Connection...

Page 15: ...e X40 Connection Significance X40 2 RXD X40 3 TXD X40 5 GND X40 7 RTS X40 8 CTS Cable Screen GND Audio Line out Interface X42 Connection Significance X42 1 GND X42 2 Line out R X42 3 Line out L Audio...

Page 16: ...5 not available Connection Significance X45 2 GND X45 3 GND X45 4 5V DC Brightness sensor BS Interface X45 Connection Significance X45 1 BS X45 2 GND X45 3 GND The terminal numbers are written on term...

Page 17: ...nsically safe circuits or the device with supply and signal lines have to be installed in such a way that no faults can occur between the individual circuits ensure the installation is in accordance w...

Page 18: ...ith the devices which are returned to GeCma Components electronic GmbH or their agent for repair The following measures are to be taken before sending a device in for repair Please clean the device th...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ......

Page 41: ......

Page 42: ......

Reviews: