HeatStar 4000IDG-HD Operating Instructions And Owner'S Manual Download Page 2

Indirect Fired Construction Heater

Operating Instructions and Owner’s Manual

2

,

 WARNING:

YOUR SAFETY IS IMPORTANT TO YOU AND TO 
OTHERS, SO PLEASE READ THESE INSTRUCTIONS 
BEFORE YOU OPERATE THIS HEATER.

  GENERAL HAZARD WARNING:

• 

FAILURE TO COMPLY WITH THE PRECAUTIONS 
AND INSTRUCTIONS PROVIDED WITH THIS 
HEATER, CAN RESULT IN DEATH, SERIOUS 
BODILY INJURY AND PROPERTY LOSS OR 
DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, 
BURN, ASPHYXIATION, CARBON MONOXIDE 
POISONING, AND/OR ELECTRICAL SHOCK.

• 

ONLY PERSONS WHO CAN UNDERSTAND AND 
FOLLOW THE INSTRUCTIONS SHOULD USE OR 
SERVICE THIS HEATER.

• 

IF YOU NEED ASSISTANCE OR HEATER 
INFORMATION SUCH AS AN INSTRUCTIONS 
MANUAL, LABELS, ETC. CONTACT THE 
MANUFACTURER.

 WARNING:

NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING:

FIRE, BURN, INHALATION, AND 

EXPLOSION HAZARD.KEEP SOLID COMBUSTIBLES, 
SUCH AS BUILDING MATERIALS, PAPER OR CARD-
BOARD, A SAFE DISTANCE AWAY FROM THE HEATER 
AS RECOMMENDED BY THE INSTRUCTIONS NEVER 
USE THE HEATER IN SPACES WHICH DO OR MAY 
CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, 
OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, 
PAINT THINNER, DUST PARTICLES OR UNKNOWN 
CHEMICALS.

CONTENTS

WARINGS …………………………….......……………..……...2
SPECIFICATIONS ……………………………………………......3
INSTALLATION  ………………………………………………......…5
OPERATING INSTRUCTIONS………………….……………...6
MAINTENANCE…………………………………………….……7
VENTILATION………………………………………………....…7
TROUBLE SHOOTING…………………………………….….…8
WIRING DIAGRAMS…………………………….......………..9
PARTS DIAGRAM/LIST...........................................11-13

WARRANTY...............................................................14

WARNING:

READ THE INSTRUCTIONS GIVEN IN THIS

MANUAL BEFORE USING THE APPLIANCE.

• 

DO NOT USE GASOLINE, NAPHTHA OR 

VOLATILE FUELS.

• 

THE ELECTRICAL SYSTEM TO WHICH THE 

APPLIANCE IS CONNECTED MUST COMPLY 

WITH ALL SAFETY REGULATIONS IN FORCE. A 

RESIDUAL CURRENT CIRCUIT BREAKER MUST 

BE PROVIDED ON THE MAIN DISTRIBUTION 

BOARD.

• 

UNPLUG THE HEATER BEFORE ATTEMPTING 

ANY SERVICE OR MAINTENANCE.

• 

ALWAYS CHECK THE POWER SUPPLY 

CABLE BEFORE USE. IT MUST NOT BE BENT, 

CRUSHED, OR ANYWAY DAMAGED.

• 

THE POWER SUPPLY CABLE MUST BE RE-

PLACED ONLY BY QUALIFIED PERSONNEL.

• 

ONLY USE AN ORIGINAL H07RN-F POWER 

CABLE WITH WATERPROOF PLUG.

• 

DO NOT TOUCH THE EXHAUST GAS OUTLET.  

DANGER OF BURNS!

    WARNING

: This product can expose you to chem-

icals including lead and lead compounds, which are 
known to the State of California to cause cancer and 
birth defects or other reproductive harm. Wash your 
hands after handling this product. For more informa-

tion visit www.P65Warnings.ca.gov.

   WARNING

: Fuels used in liquefied propane gas 

appliances, and the products of combustion of such 
fuel, can expose you to chemicals including benzene, 
which is known to the State of California to cause 
cancer and cause birth defects or other reproductive 

harm. For more information visit www.P65Warnings.

ca.gov.

Summary of Contents for 4000IDG-HD

Page 1: ...D OWNER S MANUAL INDIRECT FIRED PORTABLE HEATER This is a vented portable heater It uses air oxygen from the area in which it is used Adequate combustion air and ventilation must be provided Refer to...

Page 2: ...INSTRUCTIONS 6 MAINTENANCE 7 VENTILATION 7 TROUBLE SHOOTING 8 WIRING DIAGRAMS 9 PARTS DIAGRAM LIST 1 1 13 WARRANTY 14 WARNING READ THE INSTRUCTIONS GIVEN IN THIS MANUAL BEFORE USING THE APPLIANCE DO N...

Page 3: ...onnected to an electrical switchboard When the heater is connected to a flue pipe the flue pipe shall terminate in a vertical section at least 3 feet long and sufficient draft shall be created to assu...

Page 4: ...TION ELECTRODE 7 COOLING FAN 8 9 10 11 12 13 14 8 PHASE NEUTRAL LINE TEST PUSH BUTTON 9 RESET BUTTON HOLD FOR 3 SEC 10 HEATING SWITCH 1 1 ROOM THERMOSTAT PLUG 12 VENTILATION MODE SWITCH 13 POWER LED 1...

Page 5: ...fied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code WARNING Never use free flames to detect gas leaks The following operations must now be carried out Plug in th...

Page 6: ...scribed in Tab I and by following instruction After having moved the handle into the opposite position put again the fixing screw and a new sticker on it stating the gas which has to be used a number...

Page 7: ...ent of H T connectors to the electrodes and check H T cables remove burner assembly clean and check electrode settings adjust according to scheme GAP OF ELECTRODES Flue Connections Diagram VENTILATION...

Page 8: ...V transformer Flame control box defective Replace control box Photocell defective Clean or replace photocell Not enough or no fuel at all at burner Check state of motor pump plastic coupling Check fue...

Page 9: ...OLENOID VALVE 1 AP CONTROL BOX EV2 SOLENOID VALVE 2 FA FAN THERMOSTAT FO PHOTOCELL CN CONNECTOR CO CONDENSER RF HEATER FILTER MV FAN MOTOR LI2 OVERHEAT SAFETY ST ELECTRIC PILOT PE GROUND DRAWING LEGEN...

Page 10: ...al 57 58 59 62 45 46 47 49 53 23 60 01 02 04 26 05 10 09 12 A 28 22 B 21 06 37 27 28 03 25 42 43 36 41 82 85 84 83 80 24 38 56 17 18 35 C 30 29 40 39 11 20 16 19 32 Optional 08 07 100 101 78 68 67 66...

Page 11: ...E10324 FUSE 25A 49 N A E20319 Ground terminal board 50 50731 E20305 Terminal Board 12 pin 51 E10938 H T Transformer 52 E40234 Flame Control Box REF P N ALT DESCRIPTION 53 G06073 Support Plate 56 5032...

Page 12: ...Instructions and Owner s Manual 12 HS4000 IDG ENERCO GROUP INC Indirect Fired Portable Heater 12 Operating Instructions and Owner s Manual 147 126 126 127 130 131 129 132 128 103 130 131 134 138 143...

Page 13: ...Wheel Locking Pin 138 40524 G06422 Reinforcement Plate 139 G06461 9005 Support 140 40527 G06425 9005 Panel 141 40526 G06424 9005 40526 142 40525 G06423 9005 Handle 143 40505 C10203 Handle 144 40535 M...

Page 14: ...purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or...

Page 15: ...sez quiconque n ayant pas lu les pr sentes instructions d assembler d allumer d ajuster ou de faire fonctionner cette fournaise INSTRUCTIONS D UTILISATION ET MANUEL DU PROPRI TAIRE APPAREIL DE CHAUFFA...

Page 16: ...T R SIDUEL DOIT TRE FOURNI SUR LE PANNEAU DE DISTRIBUTION PRINCIPAL D BRANCHEZ LA FOURNAISE AVANT D ESSAYER TOUT ENTRETIEN OU R PARATION V RIFIEZ TOUJOURS LE C BLE D ALIMENTATION AVANT L UTILISATION I...

Page 17: ...fum e ce dernier doit se terminer en une section verticale d une longueur d au moins 61 cm 2 pi et un courant d air suf fisant doit tre cr pour garantir un fonctionnement s curitaire et ad quat de l a...

Page 18: ...UMAGE 7 VENTILATEUR DE REFROIDISSEMENT 8 9 10 11 12 13 14 8 BOUTON POUSSOIR DE TEST DE LIGNE PHASE NEUTRE 9 BOUTON DE R INITIALISATION 10 INTERRUPTEUR DE CHAUFFAGE 1 1 PRISE DE THERMOSTAT DE LA PI CE...

Page 19: ...e la manipulation des gaz liqu fi s et au Code national CSA B149 1 d installation du gaz naturel et du propane AVERTISSEMENT Ne jamais utiliser des flammes nues pour d tecter les fuites de gaz Les op...

Page 20: ...le type de gaz utilis plusieurs diff rents autocollants sont fournis avec l appareil AVERTISSEMENT La pression du br leur ne doit pas tre ajust e l appareil de chauffage est pr t recevoir le nouveau t...

Page 21: ...rim v rifiez le bon raccord des connecteurs de haute tension aux lectrodes et v rifiez les c bles de haute tension Retirez l as semblage du br leur nettoyez et v rifiez les r glages de l lectrode r gl...

Page 22: ...use Remplacez la bo te de contr le Cellule photo lectrique d fectueuse Nettoyez ou remplacez la cellule photo lectrique Manque ou aucun carburant au niveau du br leur V rifiez l tat du couplage plasti...

Page 23: ...n 16 ou 18 ou l quivalent tel que pr cis aux pr sentes MOD LE S RIE 4000IDG FU FUSIBLE RV TEMP IT TRANSFORMATEUR DE HAUTE TENSION TA THERMOSTAT POUR LA PI CE LV1 THERMOSTAT DE SURCHAUFFE RE RELAIS EV1...

Page 24: ...Portable Heater 11 Operating Instructions and Owner s Manual 57 58 59 62 45 46 47 49 53 23 60 01 02 04 26 05 10 09 12 A 28 22 B 21 06 37 27 28 03 25 42 43 36 41 82 85 84 83 80 24 38 56 17 18 35 C 30 2...

Page 25: ...50093 E20508 PORTE FUSIBLE 47 40508 E10324 FUSIBLE 25 A 49 N A E20319 Panneau de borne de terre 50 50731 E20305 Borne panneau 12 broches 51 E10938 Transformateur HT 52 E40234 Bo tier de commande de f...

Page 26: ...alimentation indirecte pour construction Instructions d utilisation et manuel du propri taire HS4000 IDG ENERCO GROUP INC Indirect Fired Portable Heater 12 Operating Instructions and Owner s Manual 14...

Page 27: ...ondelle 137 40534 M20505 Goupille de blocage de la roue 138 40524 G06422 Plaque de renfort 139 G06461 9005 Support 140 40527 G06425 9005 Panneau 141 40526 G06424 9005 40526 142 40525 G06423 9005 Poign...

Page 28: ...les d tails concernant la r clamation De plus indiquez la date d achat et le nom et l adresse du fournisseur duquel vous avez achet notre produit Ce qui pr c de est la pleine tendue de la responsabili...

Reviews: