![Heatrae Sadia Megaflo Eco 125DD Manual Download Page 6](http://html1.mh-extra.com/html/heatrae-sadia/megaflo-eco-125dd/megaflo-eco-125dd_manual_2117687006.webp)
6
70D
125DD
145DD
170DD
210DD
250DD
300DD
Max direct kW rating
3
6
6
6
6
6
6
Immersion heat up times
(Btm immersion, 3kW)
75
139
175
193
205
267
309
Immersion heat up times
(Top immersion, 3 kW)
N/A
65
83
87
89
96
92
Immersion heat up times
(Both immersions, 6kW)
N/A
62
79
88
90
98
93
Heat loss (kW/24hrs)
0.91
1.05
1.18
1.20
1.42
1.61
1.69
Hot water capacity (volume to >40°C)
83
126
152
178
191
238
286
Weight empty (kg)
23
25
31
34
38
46
56
Weight full (kg) ¹
115
165
183
216
237
282
339
Volume (Litres) ¹
92
140
152
182
199
236
283
Max mains pressure
1.6MPa (16 bar)
Max design pressure
0.8MPa (8 bar)
Operating pressure/PRV set pressure
0.3MPa (3 bar)
Expansion relief valve setting
0.8MPa (8 bar)
T&P valve setting
1.0MPa (10 bar)/90°C
T&P Part number
95 605 810
Immersion heater electrical rating
3.0kW@240V/2.8kW@230V ~
Notes:
1: at 3 bar water inlet pressure
2:Tested to EN 60379:2004
Table 2: Technical data - Direct Cylinders
210DDD
210DDDD
250DDD
250DDDD
300DDD
300DDDD
Max direct kW rating
9
12
9
12
9
12
Immersion heat up times (9kW)
68
68
81
81
97
97
Immersion heat up times (12kW)
N/A
51
N/A
60
N/A
73
Heat loss (kW/24hrs)
1.42
1.42
1.61
1.61
1.69
1.69
Hot water capacity (volume to >40°C)
191
191
238
238
286
286
Weight empty (kg)
39
40
47
48
57
58
Weight full (kg) ¹
237
237
282
283
339
339
Volume (Litres) ¹
198
197
235
235
282
281
Max mains pressure
1.6MPa (16 bar)
Max design pressure
0.8MPa (8 bar)
Operating pressure/PRV set pressure
0.3MPa (3 bar)
Expansion relief valve setting
0.8MPa (8 bar)
T&P valve setting
1.0MPa (10 bar)/90°C
T&P Part number
95 605 810
Immersion heater electrical rating
3.0kW@240V/2.8kW@230V ~
Summary of Contents for Megaflo Eco 125DD
Page 34: ...34 Benchmark checklist...
Page 35: ...35 Commissioning service records...
Page 38: ...38 NOTES...
Page 39: ...39 NOTES...