![Heatrae Sadia Megaflo Eco 125DD Manual Download Page 5](http://html1.mh-extra.com/html/heatrae-sadia/megaflo-eco-125dd/megaflo-eco-125dd_manual_2117687005.webp)
5
3. Technical specifications
Table 1: Technical data - Indirect Cylinders
Notes:
1: at 3 bar water inlet pressure
2: at 80°C - +/- 2°C
3: Although the primary coil pressure rating is 1.0MPa (10bar) the 2 port zone valve and coil compression nuts supplied with
the cylinder is only rated 0.86MPa (8.6 bar). If the cylinder is to be plumbed into a system delivering 1.0MPa (10 bar) a
suitable 2 port zone valve and the coil compression nuts supplied will have to be sourced.
4:Tested to EN 12897:2006
70i
125i
145i
170i
210i
210i
250i
250i
300i
300i
Max direct kW rating
3
3
3
3
3
6
3
6
3
6
Immersion heat up times
(Btm immersion, 3kW)
75
139
167
179
208
208
252
252
294
294
Immersion heat up times
(Top immersion, 3 kW)
N/A
N/A
N/A
N/A
N/A
86
N/A
92
N/A
94
Immersion heat up times
(Both immersions, 6kW)
N/A
N/A
N/A
N/A
N/A
90
N/A
100
N/A
104
Coil surface area (m²)
0.58
0.58
0.72
0.79
0.79
0.79
0.79
0.79
0.79
0.79
Coil heat up times
15l/min
12.5
21.9
23.2
31.5
32.0
32.0
40.1 40.1
42.3
42.3
30l/min
12.0
17.4
20.0
25.1
25.3
25.3
34.6 34.6
35.5
35.5
45/min
9.6
15.3
17.0
23.3
24.1
24.1
26.8 26.8
33.1
33.1
Coil rating (kW) ²
15l/min
19.8
19.5
20.9
19.4
19.4
19.4
19.5 19.5
20.5
20.5
30l/min
23.4
25.1
25.0
25.1
25.3
25.3
24.2 24.2
25.4
25.4
45l/min
27.4
27.8
28.8
26.8
26.8
26.8
28.9 28.9
28.3
28.3
Pressure drop through
coil
15l/min
0.005 MPa (0.05 bar)
30l/min
0.018 MPa (0.18 bar)
45l/min
0.030 MPa (0.30 bar)
Heat loss (kW/24hrs)
0.91
1.05
1.18
1.20
1.42
1.42
1.61
1.61
1.69
1.69
Hot water capacity (volume to >40°C) 87.4
139
159
197
200
200
240
240
284
284
Weight empty (kg)
25
31
35
39
43
44
50
51
58
59
Weight full (kg) ¹
117
168
190
217
238
238
283
283
341
341
Volume (Litres) ¹
92
137
155
178
195
194
233
232
283
282
Max mains pressure
1.6MPa (16 bar)
Max design pressure
0.8MPa (8 bar)
Operating pressure/PRV set pressure
0.3MPa (3 bar)
Max primary pressure ³
1.0MPa (10 bar)
Expansion relief valve setting
0.8MPa (8 bar)
T&P valve setting
1.0MPa (10 bar)/90°C
T&P Part number
95 605 810
Immersion heater electrical rating
3.0kW@240V/2.8kW@230V ~