Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to completely cool.
• Run continuously on high an additional 12 hours.
This cures the materials used to manufacture the fire-
place.
NOTICE!
Open windows for air circulation during fireplace
break-in.
• Some people may be sensitive to smoke and
odors.
• Smoke detectors may activate.
I. After Fireplace is Lit
K. Frequently Asked Questions
ISSUE
SOLUTIONS
Condensation on the glass
This is a result of gas combustion and temperature variations. As the appliance warms, this
condensation will disappear.
Blue flames
This is a result of normal operation and the flames will begin to yellow as the appliance is allowed
to burn for 20 to 40 minutes.
Odor from appliance
When first operated, this appliance may release an odor for the first several hours. This is
caused by the curing of materials from manufacturing. Odor may also be released from finishing
materials and adhesives used near the appliance. These circumstances may require additional
curing related to the installation environment.
Film on the glass
This is a normal result of the curing process of the paint and logs. Glass should be cleaned within
3 to 4 hours of initial burning. A non-abrasive cleaner such as gas appliance glass cleaner may
be necessary. See your dealer.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
Is it normal to see the pilot
flame burn continually?
In an IntelliFire ignition system (IPI), the pilot flame should turn off when appliance is turned off.
Some optional control systems available with IPI models may allow pilot flame to remain lit. In a
standing pilot system the pilot will always stay on.
J. Flame Adjustment Control
Some appliances come equipped with a high/low flame
adjustment control.
• Open control access panel
• Compare your valve to Figures 2.4 & 2.5.
• Adjust the flame by turning knob as indicated in the
photo matching your valve.
HI
LO
Indicator
Indicator
HI
LO
Figure 2.4 DEXEN Valve - IntelliFire Ignition System